Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GENERAL GONZALEZ ENTERPRISE INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GENERAL GONZALEZ ENTERPRISE INC. in 17 FIELDSTONE STREET, WESTFORD, MA 01886 (NAICS 238350). OSHA activity number 347450959.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Gonzalez Enterprise INC. — free Get an email when a new federal OSHA severe-injury report for General Gonzalez Enterprise INC. is published. One employer, no account, unsubscribe in one click.
Site address
17 FIELDSTONE STREET
City
WESTFORD
State
MA
ZIP
01886
Mailing
163 CHERRY STREET APT 1, ASHLAND, MA 01721
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238350
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.451 A06

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 22, 2024
Abate by
Dec 10, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR  1926.451(a)(6): Scaffolds were not designed by a qualified person  Location garage area   On or about 5/1/2024, a pump jack scaffold system was not designed or constructed by a qualified person.
Recent events (1)
  • — Z (S) $4839

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 22, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR  1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.     Location: garage area   On or about 5/1/2024, the pump jack scaffold platform did not have a direct access from a lower level and an employee accessed the scaffold platform via climbing adjacent  work trailer.
Recent events (1)
  • — Z (S) $4839

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 22, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR  1926.451(g)(1):Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  Location garage area   On or about 5/1/2024, an employee working on a pump jack scaffold more than 10 feet above the lower level was exposed to fall hazards due to no scaffold end rails or other fall protection devices.
Recent events (1)
  • — Z (S) $4839

1926.452 J02

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 22, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR  1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.   Location garage area   On or about 5/1/2024, the pump jack legs were not secured to the building at the bottom of the scaffold pole.
Recent events (1)
  • — Z (S) $4839

1926.1053 B04

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 22, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR  1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  Location garage area   On or about 5/1/2024, a extension ladder was used as the pump jack scaffold midrail as well as work surface for building materials.
Recent events (1)
  • — Z (S) $4839

1926.451 C02

Other-than-serious 1 instance 1 exposed
Issued
Oct 22, 2024
Penalty
Initial $388 · Current $388
29 CFR  1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates and mud sills or other adequate firm foundation:   Location garage area   On or about 5/1/2024, the pump jack scaffold legs were not supported by mudsills and rested directly on asphalt.
Recent events (1)
  • — Z (O) $388

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347450959.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.