LEOLA, PA —
OSHA Inspection: KABAR PRODUCTS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KABAR PRODUCTS, LLC in 98 E. MAIN STREET, LEOLA, PA 17540 (NAICS 333992). OSHA activity number 347461022.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KABAR PRODUCTS, LLC
- Site address
- 98 E. MAIN STREET
- City
- LEOLA
- State
- PA
- ZIP
- 17540
- Mailing
- 98 EAST MAIN STREET, LEOLA, PA 17540
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333992
- Employees
- 40
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.37 A03
- Issued
- Sep 25, 2024
- Abate by
- Jan 16, 2025
- Penalty
- Initial $6,453 · Current $0 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not kept free and unobstructed: (a) Welding Area, West Side of Building - Materials and equipment, including, but not limited to, a piece of practice angle iron on the floor and a pedestal fan in front of the exit door, and frame rotating equipment between the building's central aisleway and the west exit door (where the natural gas piping enters the building), obstructed access to this exit door, on or about May 6, 2024. (b) Welding Area, East Side of Building - Materials and equipment, including, but not limited to a frame and frame rotating equipment between the building's central aisleway and the east exit door, obstructed access to this exit door, on or about May 6, 2024. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (S) $6453
1910.178 A04
- Issued
- Sep 25, 2024
- Abate by
- Jan 15, 2025
- Penalty
- Initial $8,067 · Current $10,000
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: (a) 98 East Main Street, Leola, Pennsylvania - To reach elevated work, employees used two in-house made personnel platforms on the forks of any one of the following powered industrial trucks: Nissan forklift (model BGF03A45V, chassis number BGF03-920953), UniCarriers forklift (model MUG1F2A35LV, chassis number UG1F2-9L21014), or UniCarriers forklift (model MUG1F2A35LV, chassis number UG1F2-9L21246). The employer did not get the forklift manufacturers' prior written approval to use the attachments, which could result in hazards such as overloading the forklift or dropping a personnel platform and its occupants, on or about May 8, 2024. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $10000
- — Z (S) $8067
1910.178 O01
- Issued
- Sep 25, 2024
- Abate by
- Jan 15, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(o)(1): The employer did not ensure that only stable or safely arranged loads were handled: (a) 98 East Main Street, Leola, Pennsylvania - To reach elevated work, employees used a large in-house made personnel platform (with a rusted patina) on the forks of any one of the following powered industrial trucks: Nissan forklift (model BGF03A45V, chassis number BGF03-920953), UniCarriers forklift (model MUG1F2A35LV, chassis number UG1F2-9L21014), or UniCarriers forklift (model MUG1F2A35LV, chassis number UG1F2-9L21246). This platform had no means for secure attachment to the lifting carriage and forks, which could result in dropping the personnel platform and its occupants, on or about May 8, 2024. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G04
- Issued
- Sep 25, 2024
- Abate by
- Jan 15, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4): Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph [General Industry reference 1910.27(a)]: (a) 98 East Main Street, Leola, Pennsylvania - To reach elevated work, employees used an in-house made personnel platform (with orange guardrails) elevated on the forks of any one of the following powered industrial trucks: Nissan forklift (model BGF03A45V, chassis number BGF03-920953), UniCarriers forklift (model MUG1F2A35LV, chassis number UG1F2-9L21014), or UniCarriers forklift (model MUG1F2A35LV, chassis number UG1F2-9L21246). The guardrail on this personnel platform did not meet the requirements of a guardrail system in that the side where employees entered the platform had a chain at the height of a top rail but had no mid-rail or other intermediate member, exposing employees to the hazard of falling to a lower level, on or about April 1, 2024. (b) 98 East Main Street, Leola, Pennsylvania - To reach elevated work, employees used a large in-house made personnel platform (with a rusted patina) on the forks of any one of the following powered industrial trucks: Nissan forklift (model BGF03A45V, chassis number BGF03-920953), UniCarriers forklift (model MUG1F2A35LV, chassis number UG1F2-9L21014), or UniCarriers forklift (model MUG1F2A35LV, chassis number UG1F2-9L21246). The guardrail on this personnel platform did not meet the requirements of a guardrail system in that it had only a top rail and no mid-rail or other intermediate member and had no guardrail at the opening for the integrated ladder. In addition, the top rail had become completely detached from an upright on one end of the platform, exposing employees to the hazard of falling to a lower level, on or about May 8, 2024. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
5(a)(1)
- Issued
- Sep 25, 2024
- Abate by
- Jan 15, 2025
- Penalty
- Initial $6,453 · Current $10,000
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) 98 East Main Street, Leola, Pennsylvania ? employees were utilizing machines with various moving part hazards, on or about May 6, 2024. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $10000
- — Z (S) $6453
1910.212 A03 II
- Issued
- Sep 25, 2024
- Abate by
- Oct 22, 2024
- Penalty
- Initial $6,453 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Points of operation of machinery were not guarded to prevent employees from having any part of their body in the danger zones during operating cycles: (a) Welding Area (northeast area) - Employees hand-fed parts into and used a foot pedal to actuate the Uni-Hydro ironworker, model 66-24, serial number 1P66983X. The station used to bend clips and to stamp grate guide pins had no guarding, and the station used to punch holes in clips had no guarding, exposing employees to the hazards of getting hands and fingers struck-by or caught-in the points of operation, on or about April 1, 2024. (b) Shear and Press Area - Employees hand-fed metal parts into and used a foot pedal to actuate the Cincinnati mechanical shear, and the point of operation had no guarding, exposing employees to getting struck-by the shear blade, on or about May 6, 2024. (c) Shear and Press Area - Employees hand-fed metal parts into and used a foot pedal to actuate the Pacific hydraulic shear, model 600 G12, serial number S11176. The fixed guard at the right side of the machine had become detached, which would allow employees' fingers and hands to reach into the shear blade at the right side of the machine, on or about May 6, 2024. (d) Shear and Press Area - Employees hand-fed metal parts into and used a foot pedal to actuate the Pacific hydraulic press brake, and the point of operation had no guarding, exposing employees to the hazards of getting hands and fingers struck-by or caught-in the point of operation, on or about May 6, 2024. (e) Shear and Press Area - Employees hand-fed metal parts into and used a foot pedal to actuate the Cincinnati mechanical press brake, series 12, serial number 37055, equipped with a punch, and the punch had no guarding, exposing employees to the hazards of getting hands and fingers struck-by or caught-in the point of operation, on or about May 6, 2024. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $6453
1910.219 C02 I
- Issued
- Sep 25, 2024
- Abate by
- Oct 22, 2024
- Penalty
- Initial $6,453 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven feet or less from floor or working platform were not protected by stationary casings enclosing shafting completely or by troughs enclosing sides and top or sides and bottom of shafting: (a) Shear and Press Area - The horizontal shaft, 39.25 inches above the floor, between the three strands of chains on the end of the chain conveyor at the rear of the Pacific hydraulic shear, model 600 G12, serial number S11176, had no guarding, exposing employees to caught-in and entanglement hazards, on or about May 6, 2024. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $6453
1910.219 C04 I
- Issued
- Sep 25, 2024
- Abate by
- Oct 22, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft ends did not present a smooth edge and end and projected more than one-half the diameter of the shaft: (a) Shear and Press Area - The 1.5-inch diameter horizontal drive shaft, between the three strands of chains on the chain conveyor at the rear of the Pacific hydraulic shear, model 600 G12, serial number S11176, had an unguarded end with a keyway and that projected 4.75 inches, exposing employees to caught-in and entanglement hazards, on or about May 6, 2024. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 B04 II B
- Issued
- Sep 25, 2024
- Penalty
- Initial $6,453 · Current $0 Reduced
General-duty citation text
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord- and plug-connected load in excess of the maximum specified in Table S-4: (a) Welding Area - Employees used a 15-amp six-outlet current tap, plugged into the two-outlet receptacle box (located to the left of the exit door where the natural gas line enters the building), to power equipment such as a fan, portable grinder, speaker, and battery charger, exposing employees to electrical and fire hazards, on or about May 6, 2024. No abatement certification or documentation required.
Recent events (2)
- — I (S) $0
- — Z (S) $6453
1910.305 G01 IV
- Issued
- Sep 25, 2024
- Abate by
- Oct 22, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv): (a) Welding Area - Employees used a triple-outlet, two-foot long flexible cord, plugged into the bottom outlet of the two-outlet receptacle box (located to the right of where the natural gas line enters the building), instead of fixed wiring, to power equipment such as a frame rotator, exposing employees to electrical and fire hazards, on or about May 6, 2024. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 I
- Issued
- Sep 25, 2024
- Abate by
- Jan 15, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): (a) Welding Area - The employer did not visually inspect equipment before use as evidenced by a yellow extension cord where the outer jacket had separated from the cord's plug end. Employees had this cord plugged into a 15-amp six-outlet current tap, plugged into the two-outlet receptacle box (located to the left of the exit door where the natural gas line enters the building), for use in powering equipment such as a portable grinder, exposing employees to electrical and fire hazards, on or about May 6, 2024. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Kabar Products, LLC
View Kabar Products, LLC's full OSHA safety record →
More inspections in this industry (NAICS 333992)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347461022.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.