OSHA Inspection: NEXTRISE USA INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of NEXTRISE USA INC. in 5000 I-10 WAREHOUSE #6 LINE #1, SEALY, TX 77474 (NAICS 332312). OSHA activity number 347461444.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nextrise USA INC. — free Get an email when a new federal OSHA severe-injury report for Nextrise USA INC. is published. One employer, no account, unsubscribe in one click.
Establishment
NEXTRISE USA INC.
Site address
5000 I-10 WAREHOUSE #6 LINE #1
City
SEALY
State
TX
ZIP
77474
Mailing
5000 I-10 WAREHOUSE #6 LINE 1, SEALY, TX 77474
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
21
Ownership type
A

7 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 4 instances 3 exposed
Issued
Oct 24, 2024
Abate by
Nov 20, 2024
Penalty
Initial $4,610 · Current $2,300 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about April 24, 2024, at the Un-Coiler, Pipe Forming, Automatic Welding and Bundling area; employees were working in proximity to rotating equipment and moving parts without guarding at the point operation while conducting pipe fabrication activities.
Recent events (2)
  • — I (S) $2300
  • — Z (S) $4610

1910.243 C03

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Oct 24, 2024
Abate by
Nov 20, 2024
Penalty
Initial $3,687 · Current $0 Reduced
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel:  On or about April 24, 2024, in the zincing process area; employees were grinding metal piping using a handheld grinder without the use of equipment guarding while performing fabrication assembly.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3687

1910.252 B02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 24, 2024
Abate by
Nov 20, 2024
Penalty
Initial $3,687 · Current $1,800 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not required to wear appropriate goggles to protect them from the rays when noncombustible or flameproof screens or shields were not used.  On or about April 24, 2024, at the Un-Coiler area; employees were welding without the use of protective screens/barriers to shield other personnel in the area from noise, fumes, and UV light exposures.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3687

1910.303 B06

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 24, 2024
Abate by
Nov 20, 2024
Penalty
Initial $4,610 · Current $2,300 Reduced
29 CFR 1910.303(b)(6): Deteriorating agents. Unless identified for use in the operating environment, conductors and/or equipment will not be located in damp or wet locations; or where exposed to gases, fumes, vapors, liquids, or other agents that have a deteriorating effect on the conductors or equipment; or where exposed to excessive temperatures.  On or about April 24, 2024, at the pipe forming equipment and conveyor/packing area; an employee was fabricating and bundling piping in proximity to high voltage power cables in standing water while the employee stood on metal grating operating the equipment.
Recent events (2)
  • — I (S) $2300
  • — Z (S) $4610

1910.334 A02 I

Serious Gravity 5 4 instances 2 exposed
Issued
Oct 24, 2024
Abate by
Nov 20, 2024
Penalty
Initial $3,687 · Current $3,500 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  On or about April 24, 2024, throughout the facility; employees were utilizing electrical cords and cables that were not inspected for defects prior to use, exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $3687

1910.305 G02 III

Serious Gravity 5 2 instances 3 exposed
Issued
Oct 24, 2024
Abate by
Nov 20, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(2)(iii):Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  On or about April 24, 2024, throughout the facility; employees were utilizing and working in proximity to power cords, extension cords, and other cables with strain relief damage, exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 5 3 instances 2 exposed
Issued
Oct 24, 2024
Abate by
Nov 20, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(ii):There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  On or about April 24, 2024, throughout the facility; employees were utilizing multiple extension cords, power cables, and other electrical wiring that was damaged or defective, exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Nextrise USA INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347461444.