SAINT LOUIS, MO —
OSHA Inspection: ARCHWAY ANODIZE
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ARCHWAY ANODIZE in 2120 MIAMI STREET, SAINT LOUIS, MO 63118 (NAICS 332813). OSHA activity number 347463309.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARCHWAY ANODIZE
- Site address
- 2120 MIAMI STREET
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63118
- Mailing
- 2120 MIAMI STREET, SAINT LOUIS, MO 63118
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 7
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.178 L06
- Issued
- Jul 19, 2024
- Abate by
- Aug 14, 2024
- Penalty
- Initial $3,457 · Current $2,074 Reduced
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): On or about 7 May 2024, employees of Archway Anodize were operating a forklift without training and certification. At least two employees had been operating the forklift onsite without training or certification from Archway Anodize.
Recent events (2)
- — I (S) $2074.2
- — Z (S) $3457
1910.303 G01
- Issued
- Jul 19, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: On or about 7 May 2024, the employer did not ensure sufficient access and working space was provided and maintained about the energized electrical equipment including an electrical box in the sorting and storage room which was blocked by discarded boxes.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332813)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347463309.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.