CHICAGO, IL —
OSHA Inspection: CRAWFORD STEEL CO., INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CRAWFORD STEEL CO., INC. in 3141 W 36TH PL., CHICAGO, IL 60632 (NAICS 423510). OSHA activity number 347472144.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CRAWFORD STEEL CO., INC.
- Site address
- 3141 W 36TH PL.
- City
- CHICAGO
- State
- IL
- ZIP
- 60632
- Mailing
- 3141 W 36TH PL., CHICAGO, IL 60632
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423510
- Employees
- 43
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 II
- Issued
- Jul 15, 2024
- Abate by
- Aug 2, 2024
- Penalty
- Initial $8,067 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a. On or about February 12, 2024, the lockout-tagout procedure for maintenance activities, such as changing blades and adjusting knife clearance, failed to clearly identify all of the specific steps to be followed by employees to isolate and disable the Cincinnati Model: 2512G, Serial No. 48926, mechanical #2 Shear in order to safely de-energize the equipment and control the hazardous pneumatic energy. The procedure also lacked specific steps to relieve hazardous residual pneumatic energy contained in the air lines and specific verification steps were not prescribed to determine the effectiveness of the energy control measures.
Recent events (2)
- — I (S) $0
- — Z (S) $8067
1910.147 C06
- Issued
- Jul 15, 2024
- Abate by
- Aug 8, 2024
- Penalty
- Initial $8,067 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. The periodic inspection must: [A] be performed by an authorized employee other than the ones utilizing the energy control procedure being inspected. [B] be conducted to correct any deviations or inadequacies identified. [C] where lockout is used for energy control, include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. [D] where tag-out is used for energy control, include a review between the inspector and each authorized and affected employee, of that employee's responsibilities under the energy control procedure being inspected, and the elements set forth in paragraph (c)(7)(ii) of this section. a. On or about February 12, 2024, employees performing servicing or maintenance on the Cincinnati Model: 2512G Serial No. 48926 mechanical #2 Shear were exposed to hazardous energy when the employer failed to periodically inspect energy control procedures and practices to ensure that the steps in the energy control procedure are followed, the employees involved know their responsibilities under the procedure, the procedure is adequate to provide the necessary protection and what changes, if any, are needed.
Recent events (2)
- — I (O) $6000
- — Z (S) $8067
1910.147 C07 I A
- Issued
- Jul 15, 2024
- Abate by
- Aug 15, 2024
- Penalty
- Initial $8,067 · Current $9,000
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): The employer failed to provide adequate training to their authorized employee(s) in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and, and the methods and means necessary for energy isolation and control. a. #2 Cincinnati Shear - On or about February 12, 2024, the employer failed to provide training to each authorized employee performing service and/or maintenance to machinery or equipment to ensure the employee acquired the knowledge and skills required for the safe application, usage and removal of energy control devices. Machine operators and helpers were exposed to crushing and caught in injuries while performing maintenance on the Cincinnati Model: 2512G Serial No. 48926 Shear to adjust the knife clearance after following a blade change.
Recent events (2)
- — I (S) $9000
- — Z (S) $8067
1910.147 D
- Issued
- Jul 15, 2024
- Abate by
- Aug 8, 2024
- Penalty
- Initial $8,067 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedure) was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6): a. On or about February 12, 2024, employees were exposed to machine hazards associated with moving parts, in-going nip points, and caught in hazards during servicing and adjusting the knife clearance during a blade change on the #2 Cincinnati Model: 2512G Serial No. 48926 mechanical shear. The employer failed to implement energy control application steps as LOTO devices were not applied to the electrical disconnect [per the 1910.147(d)(4) requirements.] As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $8067
1910.147 F03 I
- Issued
- Jul 15, 2024
- Abate by
- Aug 8, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(3)(i): When servicing and/or maintenance is performed by a crew, craft, department or other group, they shall utilize a procedure which affords the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device. a. On or about February 12, 2024, the employer failed to ensure that four employee(s) involved in the servicing and maintenance task of changing a knife blade and adjusting the knife clearance at the Cincinnati Model: 2512G Serial No. 48926 mechanical #2 Shear utilized the established procedure which affords the employees a level or protection provided by the implementation of a personal lockout or tagout device, therefore exposing employees to crushing/pinch-point injuries to their hands and arms.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Crawford Steel CO., INC.
View Crawford Steel CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423510)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347472144.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.