Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FEDERAL EXPRESS CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FEDERAL EXPRESS CORPORATION in 200 US AIRPORTS WAY, EAST GRANBY, CT 06026 (NAICS 492110). OSHA activity number 347473985.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Federal Express Corporation — free Get an email when a new federal OSHA severe-injury report for Federal Express Corporation is published. One employer, no account, unsubscribe in one click.
Site address
200 US AIRPORTS WAY
City
EAST GRANBY
State
CT
ZIP
06026
Mailing
200 US AIRPORTS WAY, EAST GRANBY, CT 06026
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
492110
Employees
60
Ownership type
A

8 citations on file for this inspection.

1910.110 F02 II

Other-than-serious Gravity 1 2 instances 20 exposed
Issued
Jul 23, 2024
Penalty
Initial $4,848 · Current $5,000
29 CFR  1910.110(f)(2)(ii):  Liquefied petroleum gas container(s) stored inside were located near exits, stairways, or in areas normally used or intended for the safe exit of people:  On, or about, May 10, 2024, in the following locations, compressed gas cylinders that contained propane were stored next to doors identified as EXITS:  A.	Main Entrance Door:  A Blue Rhino tank. B.	Rear Door, Near Postal Operations:  Two forklift tanks.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $4848

1910.110 F04 I

Deleted Serious Gravity 1 1 instance 20 exposed
Issued
Jul 23, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.110(f)(4)(i):  The employer stored LP-Gas in a quantity exceeding 300 pounds (approximately 2550 cubic feet in vapor form) inside of a building:  Facility:  On, or about, May 10, 2024, approximately 442 pounds of propane gas was stored in tanks located at the front entrance, the rear postal area and in and in front of the propane gas storage cage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 A02

Other-than-serious Gravity 1 1 instance 4 exposed
Issued
Jul 23, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.178(a)(2):  All new powered industrial trucks acquired and used by an employer shall meet the design and construction requirements for powered industrial trucks established in the "American National Standard for Powered Industrial Trucks, Part II, ANSI B56.1-1969", which is incorporated by reference as specified in �1910.6:  Ref. Section 505.B., Ref. NFPA 505-1969, Section 602.o.    Propane Storage Area:  On, or about, May 10, 2024, a "NO SMOKING" sign had not been posted where refueling operations were conducted.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 B07 IV

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jul 23, 2024
Penalty
Initial $7,605 · Current $0 Reduced
29 CFR  1910.303(b)(7)(iv):  There existed damaged parts that could have adversely affected the safe operation or mechanical strength of electrical  equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:  Roller Deck, Scale Area:  On, or about, May 10, 2024, a wall mounted receptable was left with plug prongs projecting from the socket after it had been struck by a container.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7605

1910.305 G01 IV A

Other-than-serious Gravity 1 2 instances 20 exposed
Issued
Jul 23, 2024
Penalty
Initial $4,848 · Current $5,000
29 CFR  1910.305(g)(1)(iv)(A):  Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  On, or about, May 10, 2024, in the following locations flexible cord was used in lieu of permanent wiring:  A.	Rewrap Area:  A yellow extension cord was used to energize a label printer. B.	Former Postal Area:  A flat, white extension cord was used to energize an air conditioning unit.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $4848

1910.178 A04

Other-than-serious 1 instance 4 exposed
Issued
Jul 23, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval and capacity, operation, and maintenance instruction plates, tags or decals of the powered industrial truck were not changed accordingly:  Facility:  On, or about, May 10, 2024, Hyster forklift 23036 was equipped with longer forks than what was listed on the identification plate.  Also, markings on the forks extended the load center from 24 inches to 53 inches, which reduced the capacity of the forklift by approximately 40%.  The longer forks along with the reduced lifting capacity were not added to the identification plate.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Jul 23, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2):   Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Former Postal Work Area:  On, or about, May 10, 2024, a quad Handy box designed for permanent mounting was used in what appeared to be an extension cord assembly to energize a space heater located under a work desk.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.145 C03

Other-than-serious 1 instance 20 exposed
Issued
Jul 23, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.145(c)(3):   Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s):  Pancake Scale Area:  On or about May 10, 2024, safety instruction sign(s) and/or markings on the floor were not used to convey prohibition of storage of items in the exclusion zone around electric panels.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Federal Express Corporation's full OSHA safety record →