TAMUNING, GU —
OSHA Inspection: PACIFIC JIMI K CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PACIFIC JIMI K CORPORATION in 1797 ARMY DRIVE HARMON INDUSTRIAL PARK, TAMUNING, GU 96913 (NAICS 238160). OSHA activity number 347475113.
Where did this inspection happen?
- Establishment
- PACIFIC JIMI K CORPORATION
- Site address
- 1797 ARMY DRIVE HARMON INDUSTRIAL PARK
- City
- TAMUNING
- State
- GU
- ZIP
- 96913
- Mailing
- P.O. BOX 9597, TAMUNING, GU 96931
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B04 I
- Issued
- Penalty
- Initial $4839.00 · Current $4839.00
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. Center of the roof: Employees were removing and attaching roofing material near an uncovered hole were not protected by a guard rail, safety net, or personal fall arrest system. Employees were exposed to fall hazards.
Recent events (1)
- — Z (S) $4839
1926.501 B10
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. Edge of the roof: Employees were removing and attaching roofing material not protected by a guard rail, safety net, or personal fall arrest system. Employees were exposed to fall hazards.
Recent events (1)
- — Z (S) $0
1926.403 B02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: Across the driveway: Multiple extension cords were connected-in-series (daisy chained) to provide power to the Weiying Aerial Working Platform. Employees were exposed to electrical and fire hazards.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in GU
BARRIGADA, GU—2026-01-22
DURI CORPORATION
TAMUNING, GU—2026-01-21
DLR CORPORATION
BARRIGADA, GU—2026-01-21
DURI CORPORATION
TAMUNING, GU—2026-01-20
MG CONSTRUCTION COMPANY
BARRIGADA, GU—2026-01-20
PFM -VERTEX-LMS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347475113.