Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GALE O. BOYER ROOFING - BRIAN STETTS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GALE O. BOYER ROOFING - BRIAN STETTS, LLC in 3427 LYCOMING MALL DRIVE, MONTOURSVILLE, PA 17754 (NAICS 238160). OSHA activity number 347483844.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gale O. Boyer Roofing - Brian Stetts, LLC — free Get an email when a new federal OSHA severe-injury report for Gale O. Boyer Roofing - Brian Stetts, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3427 LYCOMING MALL DRIVE
City
MONTOURSVILLE
State
PA
ZIP
17754
Mailing
871 SHADLE ROAD, JERSEY SHORE, PA 17740
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

5 citations on file for this inspection.

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 8, 2024
Abate by
Aug 20, 2024
Penalty
Initial $4,839 · Current $2,000 Reduced
29 CFR  1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.    a) Roof: On or about May 16, 2024, an employee was engaged in roofing work while on a ladder jack scaffold without having an appropriate point of access.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (3)
  • — F (S) $2000
  • — C (S) $4839
  • — Z (S) $4839

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 8, 2024
Abate by
Aug 20, 2024
Penalty
Initial $4,839 · Current $2,000 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level:  a) Roof: On or about May 16, 2024, employees were engaged in roofing work while on ladder jack scaffolds without using fall protection.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (3)
  • — F (S) $2000
  • — C (S) $4839
  • — Z (S) $4839

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 8, 2024
Abate by
Aug 20, 2024
Penalty
Initial $4,839 · Current $2,000 Reduced
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a)  Roof: On or about May 16, 2024, an employee engaged in roofing work was exposed to fall hazards up to sixteen (16) feet from not using a conventional fall protection system.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (3)
  • — F (S) $2000
  • — C (S) $4839
  • — Z (S) $4839

1926.1053 A06 II

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 8, 2024
Abate by
Aug 20, 2024
Penalty
Initial $2,074 · Current $800 Reduced
29 CFR 1926.1053(a)(6)(ii): The rungs or steps of portable metal ladders were not corrugated, knurled, dimpled, coated with skid-resistant material, or otherwise treated to minimize slipping:  a) Ladder Hoist: On or about May 16, 2024, an employee engaged in roofing activities was exposed to a fall hazard by climbing a ladder hoist with rungs that were not corrugated, knurled, dimpled, coated with skid-resistant material, or otherwise treated to minimize slipping.  ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — F (S) $800
  • — C (S) $2074
  • — Z (S) $2074

1926.1053 B06

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 8, 2024
Abate by
Aug 20, 2024
Penalty
Initial $3,457 · Current $1,200 Reduced
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level:  a) Roof: On or about May 16, 2024, an employee engaged in roofing activities was exposed to fall hazards while using a stepladder on a slopped roof.    ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — F (S) $1200
  • — C (S) $3457
  • — Z (S) $3457