Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GREIF FIBRE DRUM, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GREIF FIBRE DRUM, INC. in 220 FRONTENAC ROAD, NAPERVILLE, IL 60563 (NAICS 322219). OSHA activity number 347489015.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Greif Fibre Drum, INC. — free Get an email when a new federal OSHA severe-injury report for Greif Fibre Drum, INC. is published. One employer, no account, unsubscribe in one click.
Site address
220 FRONTENAC ROAD
City
NAPERVILLE
State
IL
ZIP
60563
Mailing
220 FRONTENAC ROAD, NAPERVILLE, IL 60563
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322219
Employees
98
Ownership type
A

1 citation on file for this inspection.

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 12, 2024
Penalty
Initial $16,131 · Current $9,500 Reduced
29 CFR  1910.147(d):Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  On or about March 14, 2024, the employer did not ensure that employees implemented energy control steps prior to performing servicing and maintenance activities such as making adjustments on the on the bottom groover workstation on the Drum Line (MN: DAH 15, SN: 388343302/M87-58).  Hazardous energy sources (electrical and pneumatic) were not isolated, exposing employees to crushing and amputation hazards in case of unexpected start-up.   As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $9500
  • — Z (S) $16131

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347489015.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.