Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KLEEN SWEEP CHIMNEY SERVICE LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KLEEN SWEEP CHIMNEY SERVICE LLC in 5189 CLARK STATE RD, GAHANNA, OH 43230 (NAICS 238140). OSHA activity number 347497349.

Watch Kleen Sweep Chimney Service LLC — free Get an email when a new federal OSHA severe-injury report for Kleen Sweep Chimney Service LLC is published. One employer, no account, unsubscribe in one click.
Site address
5189 CLARK STATE RD
City
GAHANNA
State
OH
ZIP
43230
Mailing
P.O. BOX 416, GRANVILLE, OH 43023
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

8 citations on file for this inspection.

1926.20 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4839.00 · Current $2903.00 Reduced
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.  a. Located at the job site at 5189 Clark State Rd, Gahanna, Ohio: On or about May 21, 2024, and at times prior, Kleen Sweep Chimney Service, LLC did not ensure that programs were initiated and maintained on-site including, but not limited to, scaffold safety, tool safety, respiratory protection, fall protection/prevention, hazard communication, heat stress, personal protective equipment, ladder safety, etc. As a result, workers were exposed to fall, inhalation, and struck-by hazards while performing masonry contracting work.
Recent events (2)
  • — I (S) $2903.4
  • — Z (S) $4839

1926.21 B02

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.  a. Located at the job site at 5189 Clark State Rd, Gahanna, Ohio: On or about May 21, 2024, and at times prior, the Kleen Sweep Chimney Service, LLC. did not instruct employees on the recognition and avoidance of unsafe conditions while performing masonry work including, but not limited to, scaffold safety, tool safety, respiratory protection, fall protection/prevention, hazard communication, heat stress, personal protective equipment, ladder safety, etc. As a result, workers were exposed to fall, inhalation, and struck-by hazards while performing masonry contracting work.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $4148.00 · Current $0.00 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:  a. Located at the job site at 5189 Clark State Rd, Gahanna, Ohio: On or about May 21, 2024, Kleen Sweep Chimney Service, LLC. did not ensure that the supported scaffold that employees were working from on the roof to perform chimney repair work was fully planked between the front uprights and the guardrail supports. As a result, workers were exposed to a fall hazard of approximately 5 feet to the roof surface below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4148

1926.501 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3457.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a. Located at the job site at 5189 Clark State Rd, Gahanna, Ohio: On or about May 21, 2024, and at times prior, Kleen Sweep Chimney Service, LLC. did not ensure that employees performing masonry commercial construction work from the flat roof of the commercial building utilized fall protection or prevention measures. As a result, workers were exposed to a fall hazard of approximately 11 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3457

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $3457.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  a.  Located at the job site at 5189 Clark State Rd, Gahanna, Ohio: On or about May 21, 2024, Kleen Sweep Chimney Service, LLC. did not ensure that the 20-foot aluminum portable extension ladder utilized to access the roof was extended at least 3 feet above the upper landing surface. As a result, workers were exposed to a fall hazard of approximately 11 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3457

1926.1153 C01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4839.00 · Current $2903.00 Reduced
29 CFR 1926.1153(c)(1): Specified exposure control methods. For each employee engaged in a task identified on Table 1, the employer shall fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section.  a. Located at the job site at 5189 Clark State Rd, Gahanna, Ohio: On or about May 21, 2024, and at times prior, the employer did not implement the controls listed on Table 1 for employees exposed to respirable crystalline silica while performing tasks such as, but not limited to, grinding out mortar joints (tuckpointing) the joints of the existing chimneys. As a result, employees were exposed to inhalation hazards.
Recent events (2)
  • — I (S) $2903.4
  • — Z (S) $4839

1926.1153 G01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1153(g)(1): Written exposure control plan. The employer shall establish and implement a written exposure control plan that contains at least the following elements:  a. Located at the job site at 5189 Clark State Rd, Gahanna, Ohio: On or about April 21, 2024, Kleen Sweep Chimney Service, LLC did not develop and implement an exposure control plan for employees exposed to respirable crystalline silica while performing tasks such as, but not limited to, tuckpointing and performing chimney repairs with portable grinders and saws. As a result, workers were exposed to inhalation hazards while performing masonry construction work.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1153 I02 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1153(i)(2)(i): Employee information and training. The employer shall ensure that each employee covered by this section can demonstrate knowledge and understanding of at least the following: The health hazards associated with exposure to respirable crystalline silica; specific tasks in the workplace that could result in exposure to respirable crystalline silica; specific measures the employer has implemented to protect employees from exposure to respirable crystalline silica, including engineering controls, work practices, and respirators to be used; the contents of this section; the identity of the competent person designated by the employer in accordance with paragraph (g)(4) of this section; and the purpose and a description of the medical surveillance program required by paragraph (h) of this section.  a. Located at the job site at 5189 Clark State Rd, Gahanna, Ohio: On or about May 21, 2024, and at times prior, Kleen Sweep Chimney Service, LLC did not ensure that employees performing masonry construction and demolition work were trained on the health hazards associated with exposure to respirable crystalline silica; specific tasks in the workplace that could result in exposure to respirable crystalline silica; specific measures the employer has implemented to protect employees from exposure to respirable crystalline silica, including engineering controls, work practices, and respirators to be used; the contents of this section; the identity of the competent person designated by the employer in accordance with paragraph (g)(4) of this section; and the purpose and a description of the medical surveillance program required by paragraph (h) of this section. As a result, workers were exposed to inhalation hazards and the resulting health impacts of exposure to respirable crystalline silica while performing masonry construction and demolition work tasks including, but not limited to, tuckpointing, chimney repairs with saws, and chimney demolition. As a result, employees were exposed to inhalation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347497349.