ROCKLEDGE, FL —
OSHA Inspection: CREEKSIDE ELECTRICAL CONSULTING LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of CREEKSIDE ELECTRICAL CONSULTING LLC in 920 ROCKLEDGE BLVD., ROCKLEDGE, FL 32955 (NAICS 238210). OSHA activity number 347497893.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CREEKSIDE ELECTRICAL CONSULTING LLC
- Site address
- 920 ROCKLEDGE BLVD.
- City
- ROCKLEDGE
- State
- FL
- ZIP
- 32955
- Mailing
- 44449 WOODRIDGE DR., CALLAHAN, FL 32011
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 11
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 J02
- Issued
- Jun 18, 2024
- Penalty
- Initial $4,610 · Current $3,227 Reduced
General-duty citation text
29 CFR 1926.651(j)(2):Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) On or about May 22, 2024, at the jobsite, employees were exposed to cave in and entrapment hazards while installing electrical conduit in a type C soil trench measuring 57' long and 4' wide and 5.5' deep on the South end and 7' deep on the North end, in that, spoil piles were less than 2 feet from the edge of the excavation.
Recent events (2)
- — I (O) $3227
- — Z (S) $4610
1926.652 A01
- Issued
- Jun 18, 2024
- Penalty
- Initial $4,610 · Current $3,227 Reduced
General-duty citation text
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). a) On or about May 22, 2024, at the jobsite, employees were exposed to cave in and entrapment hazards while installing electrical conduit in a type C soil trench measuring 57' long and 4' wide and 5.5' deep on the South end and 7' deep on the North end, in that cave in protection was not provided.
Recent events (2)
- — I (O) $3227
- — Z (S) $4610
More inspections in this industry (NAICS 238210)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347497893.