LAKE GENEVA, WI —
OSHA Inspection: CUSTOM SERVICE PLASTICS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CUSTOM SERVICE PLASTICS, INC. in 1101 SOUTH WELLS ST., LAKE GENEVA, WI 53147 (NAICS 326199). OSHA activity number 347503476.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUSTOM SERVICE PLASTICS, INC.
- Site address
- 1101 SOUTH WELLS ST.
- City
- LAKE GENEVA
- State
- WI
- ZIP
- 53147
- Mailing
- 201 SHERIDAN SPRINGS ROAD, LAKE GENEVA, WI 53147
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 20
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Oct 25, 2024
- Abate by
- Nov 4, 2024
- Penalty
- Initial $12,421 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:(a) On or about May 23, 2024, the employer did not establish a program consisting of an energy control procedure to protect employees from unexpected energizing, startup or release of stored energy.
Recent events (2)
- — I (S) $0
- — Z (S) $12421
1910.147 C03 I
- Issued
- Oct 25, 2024
- Abate by
- Nov 4, 2024
- Penalty
- Initial $12,421 · Current $8,316 Reduced
General-duty citation text
29 CFR 1910.147(c)(3)(i): The tagout device used on an energy isolating device, which was capable of being locked out, was not attached at the same location that the lockout device would have been attached: On or about May 23, 2024, the employer did not ensure that employees were installing lock out devices at the same location as the tagout device while conducting maintenance.
Recent events (2)
- — I (S) $8316
- — Z (S) $12421
1910.147 C04 I
- Issued
- Oct 25, 2024
- Abate by
- Mar 31, 2025
- Penalty
- Initial $12,421 · Current $8,316 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about May 23, 2024, the employer did not ensure that procedures were developed, documented and utilized to protect employees from potentially hazardous energy.
Recent events (2)
- — I (S) $8316
- — Z (S) $12421
1910.147 C07 I
- Issued
- Oct 25, 2024
- Abate by
- Nov 4, 2024
- Penalty
- Initial $12,421 · Current $8,316 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: On or about May 23, 2024, the employer did not provide training to ensure that the energy control program is understood and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by the employees.
Recent events (2)
- — I (S) $8316
- — Z (S) $12421
More inspections at Custom Service Plastics, INC.
View Custom Service Plastics, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347503476.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.