Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DEC-USA, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DEC-USA, INC. in 1118 INDUSTRIAL PARKWAY, BRICK, NJ 08724 (NAICS 333993). OSHA activity number 347510513.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dec-Usa, INC. — free Get an email when a new federal OSHA severe-injury report for Dec-Usa, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DEC-USA, INC.
Site address
1118 INDUSTRIAL PARKWAY
City
BRICK
State
NJ
ZIP
08724
Mailing
1118 INDUSTRIAL PARKWAY, BRICK, NJ 08724
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333993
Employees
4
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 18, 2024
Penalty
Initial $3,457 · Current $2,250 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by and caught-in-between hazards:  (a) Warehouse/ equipment, storage, and testing. The employer did not ensure that the industrial steel racking system with vertical supports had base plates and was bolted to the floor.  Employees stock the shelves with spare machine parts and spare parts for machines, thus exposing the employees to struck-by and caught-in-between hazards. This condition was observed on or about 2/29/24.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3457

1910.178 L04 III

Other-than-serious 1 instance 1 exposed
Issued
Jun 18, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  a) Warehouse/test area: On or about 5/29/24, an operator of the Yale Electric forklift (Model ERC065GN48TE084, S/N A908N06669E) had not been evaluated within three years.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347510513.