Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: BRIAN STONE CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BRIAN STONE CONSTRUCTION, INC. in 18 EDGEWATER DR., TIFTON, GA 31793 (NAICS 238160). OSHA activity number 347511255.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brian Stone Construction, INC. for free Get an email when a new federal OSHA severe-injury report for Brian Stone Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
18 EDGEWATER DR.
City
TIFTON
State
GA
ZIP
31793
Mailing
1271 INDUSTRIAL PARKWAY, ADEL, GA 31620
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 26, 2024
Penalty
Initial $9,680 · Current $5,808 Reduced
29 CFR  1926.501(b)(13):  Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a)  On the roof, located at 18 Edgewater Dr., Tifton, GA, on or about May 29, 2024, the employer exposed employees to fall hazards in that employees were performing roofing work from heights greater than 12 feet, without the use of fall protection.
Recent events (2)
  • · I (S) $5808
  • · Z (S) $9680

1926.1053 B01

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 26, 2024
Penalty
Initial $4,839 · Current $2,903 Reduced
29 CFR  1926.1053(b)(1):  Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) On the rear side of the house, located at 18 Edgewater Dr., Tifton, GA, on or about May 29, 2024, the employer exposed employees to fall hazards, in that a ladder used to access and egress the roof was not properly adjusted for the side rails to extend at least three feet above the upper landing surface of the roof.
Recent events (2)
  • · I (S) $2903.4
  • · Z (S) $4839

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347511255.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.