Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MINUTE LUBE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MINUTE LUBE in 324 26TH ST E, WILLISTON, ND 58801 (NAICS 811191). OSHA activity number 347517732.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Minute Lube — free Get an email when a new federal OSHA severe-injury report for Minute Lube is published. One employer, no account, unsubscribe in one click.
Establishment
MINUTE LUBE
Site address
324 26TH ST E
City
WILLISTON
State
ND
ZIP
58801
Mailing
324 26TH ST E, WILLISTON, ND 58801
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811191
Employees
18
Ownership type
A

10 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 13, 2024
Abate by
Sep 16, 2024
Penalty
Initial $4,610 · Current $2,766 Reduced
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):    (a) On May 30, 2024, and times prior, at or near 324 26th Street East in Williston, North Dakota, employees were exposed to fall hazards of over 4 feet while accessing parts and supplies located in mezzanines that did not have a means of preventing falls through the access opening.
Recent events (2)
  • — I (S) $2766
  • — Z (S) $4610

1910.28 B08

Serious Gravity 5 4 instances 4 exposed
Issued
Aug 13, 2024
Abate by
Sep 16, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(8): Where there were repair pits, service pits, and assembly pits less than 10 feet in depth, the employer did not limit access within 6 feet (1.8 m) of the edge of the pit to authorized employees trained in accordance with � 1910.30; place floor markings at least 6 feet (1.8 m) from the edge of the pit in colors that contrast with the surrounding area; or provide a warning line at least 6 feet (1.8 m) from the edge of the pit with stanchions capable of resisting, without tipping over, a force of at least 16 pounds (71 N) applied horizontally against the stanchion at a height of 30 inches (76 cm); or provide a combination of floor markings and warning lines at least 6 feet (1.8 m) from the edge of the pit:    (a) On May 30, 2024, and times prior, at or near 324 26th Street East in Williston, North Dakota, employees were exposed to fall hazards of more than 4 feet, while working in close proximity to open repair pits which were not guarded or were alternatively protected through the requirements set forth in 29 CFR 1910.28(b)(8)(i) through (iii).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 13, 2024
Abate by
Sep 16, 2024
Penalty
Initial $3,687 · Current $2,212 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) On May 30, 2024, and times prior, at or near 324 26th Street East in Williston, North Dakota, employees were exposed to struck by hazards where a hand-operated, hydraulic press was not equipped with a barrier guard, while pressing bearings.
Recent events (2)
  • — I (S) $2212.2
  • — Z (S) $3687

1910.215 A02

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 13, 2024
Penalty
Initial $3,687 · Current $2,212 Reduced
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections:    (a) On May 30, 2024, and times prior, at or near, 324 26th Street East in Williston, North Dakota, employees were exposed to caught in hazards while using a Duracraft bench grinder to clean parts where the spindle nut guard was not installed.
Recent events (2)
  • — I (S) $2212.2
  • — Z (S) $3687

1910.215 A04

Serious Gravity 5 2 instances 3 exposed
Issued
Aug 13, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:     (a) On May 30, 2024, and times prior,  in the battery shop, at or near 324 26th Street East in Williston, North Dakota, employees were exposed to caught in/struck by hazards while operating a Dewalt DW756 Bench Grinder without work rests installed.    (b) On May 30, 2024, and times prior,  in the battery shop, at or near 324 26th Street East in Williston, North Dakota, employees were exposed to caught in/struck by hazards while operating a Duracraft 50-6-G Bench Grinder without work rests installed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 2 instances 3 exposed
Issued
Aug 13, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    (a) On May 30, 2024, and times prior,  in the battery shop, at or near 324 26th Street East in Williston, North Dakota, employees were exposed to struck by hazards while operating a Dewalt DW756 Bench Grinder without the tongue guard being adjusted to within 1/4 inch of the wheel.    (b) On May 30, 2024, and times prior,  in the battery shop, at or near 324 26th Street East in Williston, North Dakota, employees were exposed to struck by hazards while operating a Duracraft 50-6-G Bench Grinder without the tongue guard being adjusted to within 1/4 inch of the wheel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 A02

Other-than-serious 2 instances 3 exposed
Issued
Aug 13, 2024
Penalty
Initial $518 · Current $311 Reduced
29 CFR 1910.37(a)(2): Exit routes were not arranged so that employees did not have to travel toward a high hazard area:    (a) On May 30, 2024, and times prior, at or near 324 26th Street East in Williston, North Dakota, employees were exposed to fire hazards while working in battery shop, where a spare forklift LP Tank was stored in the exit route leading to the SW exit door.    (b) On  May 30, 2024, and times prior, at or near 324 26th Street East in Williston, North Dakota, employees were exposed to fire hazards while working in main shop, where an acetylene tank was stored next to the SE exit door.
Recent events (2)
  • — I (O) $310.8
  • — Z (O) $518

1910.132 D01

Other-than-serious 1 instance 2 exposed
Issued
Aug 13, 2024
Abate by
Sep 16, 2024
Penalty
Initial $518 · Current $311 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    (a)On May 30, 2024, and times prior, at or near 324 26th Street East in Williston, North Dakota, employees were exposed to eye hazards while working in the pits under automobiles to perform servicing, where an assessment of the hazards has not been conducted.
Recent events (2)
  • — I (O) $310.8
  • — Z (O) $518

1910.243 B02

Other-than-serious 1 instance 2 exposed
Issued
Aug 13, 2024
Abate by
Sep 16, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.243(b)(2): Airhose and hose connections used for conducting compressed air to utilization equipment was not designed for the pressure and service to which they were subjected:    (a) On May 30, 2024, and times prior, at or near 324 26th Street East in Williston, North Dakota, employees engaged in oil change services were exposed to struck by hazards from an air hose fitting connected with a worm-gear clamp.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 2 instances 3 exposed
Issued
Aug 13, 2024
Penalty
Initial $518 · Current $311 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    (a) On May 30, 2024, and times prior, at or near 324 26th Street East in Williston, North Dakota, employees were exposed to electrical hazards while working in the battery shop, where access to electrical panels was impeded by the storage of materials and equipment under and in front of the panel.    (b) On May 30, 2024, and times prior, at or near 324 26th Street East in Williston, North Dakota, employees were exposed to electrical hazards while working in the main shop, where access to electrical panels was impeded by the storage of materials and equipment under and in front of the panel.
Recent events (2)
  • — I (O) $310.8
  • — Z (O) $518

View Minute Lube's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347517732.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.