Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MINERALLAC COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MINERALLAC COMPANY in 100 GAST ROAD, HAMPSHIRE, IL 60140 (NAICS 335932). OSHA activity number 347518847.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Minerallac Company — free Get an email when a new federal OSHA severe-injury report for Minerallac Company is published. One employer, no account, unsubscribe in one click.
Establishment
MINERALLAC COMPANY
Site address
100 GAST ROAD
City
HAMPSHIRE
State
IL
ZIP
60140
Mailing
100 GAST ROAD, HAMPSHIRE, IL 60140
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335932
Employees
120
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 2 instances 2 exposed
Issued
Sep 6, 2024
Abate by
Nov 15, 2024
Penalty
Initial $14,518 · Current $11,000 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.  On or about May 31, 2024, the employer did not ensure a procedure for the control of potentially hazardous energy was developed for use on Machine 60 when employees are engaged in service and/or maintenance activities. Employees performed tasks such as removing stuck lids, stuck jars, or jammed parts without the means or methods to control hazardous energy sources. Employees were exposed to pinch and nip point hazards of equipment in operation which could result in caught-in, crushing and amputation injuries.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $11000
  • — Z (S) $14518

1910.147 C04 II

Deleted Serious Gravity 5 1 instance 80 exposed
Issued
Sep 6, 2024
Abate by
Oct 4, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: (A) A specific statement of the intended use of the procedure; (B) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; (C) Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and (D) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.  On or about May 31, 2024, the employer did not have lockout/tagout procedures available that clearly and specifically outlined the scope, purpose, authorization, and rules. The procedures do not have a specific statement of intended use, nor do they state specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. Employees performing service and maintenance tasks such as removing stuck lids, stuck jars, or jammed parts do not have a clear understanding of lockout/tagout or the intended use of the procedures. Employees were exposed to pinch and nip point hazards of equipment in operation which could result in caught-in, crushing and amputation injuries.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Sep 6, 2024
Abate by
Oct 4, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedures for the application of energy control (the lockout or tagout procedures) was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6).  On or about May 7, 2024, and at times prior, the employer did not ensure that employees implemented energy control application steps prior to allowing them to perform service and maintenance tasks on Machine 60, such as unjamming screws/bolts, jar, jar lids, and labels. Machine 60 was not shut down or turned off prior to employees engaging in this servicing and maintenance activity, exposing them to pinch/nip point hazards and amputation injuries.   As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.   Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Sep 6, 2024
Abate by
Nov 15, 2024
Penalty
Initial $14,518 · Current $6,000 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  On or about May 7, 2024, and at times prior, the employer did not ensure that employees who performed service and maintenance tasks on Machine 60 were adequately trained on the means and methods needed to effectively isolate and control hazardous energy sources. Employees were exposed to pinch and nip point hazards of equipment in operation which could result in caught-in, crushing and amputation injuries.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (O) $6000
  • — Z (S) $14518

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347518847.