Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VANSEAL CORPORATION DBA VRC ENGINEERED SOLUTIONS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VANSEAL CORPORATION DBA VRC ENGINEERED SOLUTIONS in 815 PAYNE ROAD, VANDALIA, IL 62471 (NAICS 326291). OSHA activity number 347523177.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vanseal Corporation DBA VRC Engineered Solutions — free Get an email when a new federal OSHA severe-injury report for Vanseal Corporation DBA VRC Engineered Solutions is published. One employer, no account, unsubscribe in one click.
Site address
815 PAYNE ROAD
City
VANDALIA
State
IL
ZIP
62471
Mailing
815 PAYNE DR., VANDALIA, IL 62471
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326291
Employees
130
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 II A

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2024
Abate by
Dec 10, 2024
Penalty
Initial $11,524 · Current $0 Reduced
29 CFR 1910.147(c)(4)(ii)(A): The energy control procedures did not contain a specific statement on the intended use of the procedure.  On or about June 3, 2024, Employees were exposed to unexpected start-up or release of stored energy while performing servicing and maintenance activities, and the procedures for French Presses D02 and D08 did not contain a specific statement on the intended use of the procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11524

1910.147 C04 II D

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2024
Abate by
Jan 15, 2025
Penalty
Initial $0 · Current $7,491
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control  On or about June 3, 2024, Employees were exposed to unexpected start-up or release of stored energy while performing servicing and maintenance activities, and the procedures for French Presses D02 and D08 did not specify how to verify the effectiveness of the lockout.
Recent events (2)
  • — I (S) $7491
  • — Z (S) $0

1910.147 C06 I A

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2024
Abate by
Jan 15, 2025
Penalty
Initial $11,524 · Current $0 Reduced
1910.147(c)(6)(i)(A)  The periodic inspection shall be performed by an authorized employee other than the ones(s) utilizing the energy control procedure being inspected. 29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:  On or about June 3, 2024, the periodic inspection of the company's energy control procedures was not conducted with the authorized employee(s) utilizing the energy control procedures during the servicing of the equipment related to the energy control procedure being inspected.
Recent events (2)
  • — I (O) $0
  • — Z (S) $11524

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2024
Abate by
Dec 10, 2024
Penalty
Initial $9,218 · Current $5,992 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  On or about June 3, 2024, Employees were exposed to electrical shock when working around the junction boxes between press F4 and F5.  The junction boxes were used as an extension cord, powering a fan.  The junction boxes were not used or installed in accordance with the listing, labeling, or certification instructions.
Recent events (2)
  • — I (S) $5992
  • — Z (S) $9218

1910.212 A01

Serious Gravity 5 2 instances 1 exposed
Issued
Nov 13, 2024
Abate by
Jan 15, 2025
Penalty
Initial $57,620 · Current $7,491 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about June 3, 2024, the back side of French Press B03 was not provided with machine guarding to protect the employee operating at that location from point of operation hazards.
Recent events (2)
  • — I (S) $7491
  • — Z (R) $57620

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347523177.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.