MECHANICSBURG, PA —
OSHA Inspection: S&L ROOFING, GUTTERS AND SIDING, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of S&L ROOFING, GUTTERS AND SIDING, LLC in 1400 BENT CREEK BOULEVARD, MECHANICSBURG, PA 17050 (NAICS 238160). OSHA activity number 347524753.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S&L ROOFING, GUTTERS AND SIDING, LLC
- Site address
- 1400 BENT CREEK BOULEVARD
- City
- MECHANICSBURG
- State
- PA
- ZIP
- 17050
- Mailing
- 371 WILDCAT TRAIL, LIVERPOOL, PA 17045
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.1053 B01
- Issued
- Jun 14, 2024
- Penalty
- Initial $4,839 · Current $4,839
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 1400 Bent Creek Boulevard, Mechanicsburg, PA, Worksite - on or about June 4, 2024, employees were performing residential roofing work, in excess of 18 feet above a lower level, while utilizing an extension ladder that was not extended at least three feet above the upper landing surface, exposing the employees to a fall hazard. No abatement certification and documentation required.
Recent events (1)
- — Z (S) $4839
1926.1053 B05 I
- Issued
- Jun 14, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a) 1400 Bent Creek Boulevard, Mechanicsburg, PA, Worksite - on or about June 4, 2024, employees were performing residential roofing work, in excess of 18 feet above a lower level, while utilizing an extension ladder that was set at angle greater than one-quarter of its working length. No abatement certification and documentation required.
Recent events (1)
- — Z (S) $0
1926.1053 B22
- Issued
- Jun 14, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall: a) 1400 Bent Creek Boulevard, Mechanicsburg, PA, Worksite, Roof - on or about June 4, 2024, employees were utilizing an extension ladder to access and egress the roof, approximately 18 feet to the upper landing surface, while carrying tools that could cause the employee to lose their balance and fall. No abatement certification.
Recent events (1)
- — Z (S) $0
1926.102 A01
- Issued
- Jun 14, 2024
- Penalty
- Initial $27,655 · Current $27,655
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gasses or vapors, or potentially injurious light radiation: a) 1400 Bent Creek Boulevard, Mechanicsburg, PA, Worksite, Roof - on or about June 4, 2024, employees are operating pneumatic nail guns without utilizing any means of eye protection. No abatement certification or documentation required.
Recent events (1)
- — Z (W) $27655
1926.501 B13
- Issued
- Jun 14, 2024
- Penalty
- Initial $32,265 · Current $32,265
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) 1400 Bent Creek Boulevard, Mechanicsburg, PA, Worksite, Roof - on or about June 4, 2024, employees are performing residential roofing work in excess of 18 feet above a lower level without utilizing any means of fall protection. No abatement certification and documentation required.
Recent events (1)
- — Z (W) $32265
More inspections at S&L Roofing, Gutters and Siding, LLC
View S&L Roofing, Gutters and Siding, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347524753.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.