Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J & M RENTAL PROPERTY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of J & M RENTAL PROPERTY in 303 E. HAMILTON ST., ALLENTOWN, PA 18109 (NAICS 238130). OSHA activity number 347525974.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J & M Rental Property — free Get an email when a new federal OSHA severe-injury report for J & M Rental Property is published. One employer, no account, unsubscribe in one click.
Site address
303 E. HAMILTON ST.
City
ALLENTOWN
State
PA
ZIP
18109
Mailing
201 N 7TH ST S 2, ALLENTOWN, PA 18102
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

10 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 25, 2024
Abate by
Dec 6, 2024
Penalty
Initial $3,457 · Current $3,457
29 CFR  1926.21(b)(2):The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury.  (a) 301 E. Hamilton St. Allentown, PA.: On or about June 3, 2024, - not all employees had received training to recognize and avoid jobsite safety hazards,
Recent events (1)
  • — Z (S) $3457

1926.102 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Nov 25, 2024
Penalty
Initial $2,074 · Current $2,074
29 CFR  1926.102(a)(1): 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles.  (a) 301 E. Hamilton St. Allentown, PA., Roof: On or about June 3, 2024, an employee was observed using a pneumatic nail gun without using eye protection.
Recent events (1)
  • — Z (S) $2074

1926.453 B02 IV

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 25, 2024
Penalty
Initial $3,457 · Current $3,457
29 CFR  1926.453(b)(2)(iv):Employee(s) working in an aerial lift were not standing firmly on the floor of the basket:  (a) 301 Hamilton St. Allentown, PA., JLG Lift truck Basket: On or about June 3, 2024, an employee was observed working from the basket of JLG Lift truck and standing on the mid-rails, instead of being firmly on the floor of the basket.
Recent events (1)
  • — Z (S) $3457

1926.453 B02 V

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 25, 2024
Abate by
Dec 6, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.453(b)(2)(v):A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift :Note:  As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated.  (a) 301 Hamilton St. Allentown, PA., JLG Aerial Lift Basket: On or about June 3, 2024, an employee was observed working from the basket of JLG aerial lift, however, a body belt was not worn by  the employee to attached to the boom or basket .
Recent events (1)
  • — Z (S) $0

1926.501 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 25, 2024
Penalty
Initial $3,457 · Current $3,457
29 CFR  1926.501(b)(1):Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  (a) 301 Hamilton St. Allentown, PA.: On or about June 3, 2024, framing employees were installing decking along the roof edge of a two-story commercial building under construction, but fall protection was not in place and employees were exposed to a fall hazard greater than 6 feet.
Recent events (1)
  • — Z (S) $3457

1926.501 B04 I

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 25, 2024
Penalty
Initial $2,765 · Current $2,765
29 CFR  1926.501(b)(4)(i):Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around/over the opening:  (a) 301 Hamilton St. Allentown, PA.: On or about June 3, 2024, employees on the second level worked around an unguarded floor opening that was 9-feet by 3-feet, exposing employees to a fall hazard greater than 6 feet.
Recent events (1)
  • — Z (S) $2765

1926.501 B04 II

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 25, 2024
Abate by
Dec 6, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.501(b)(4)(ii):Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers:  (a) 301 Hamilton St. Allentown, PA.: On or about June 3, 2024, employees had to step over an unguarded hole to use the main entrance of the newly constructed commercial structure, exposing employees to a trip hazard/hole that was 12 by 25 by 12 inches.
Recent events (1)
  • — Z (S) $0

1926.403 B01

Other-than-serious 1 instance 4 exposed
Issued
Nov 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.403(b)(1):Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:  (a) 301 E. Hamilton St. Allentown, PA., Second Level: On or about June 3, 2024, an employee was observed using a circular saw that was plugged into an electrical extension cord with a makeshift repair, due to a damaged outer jacket, exposing employees to an electrical shock hazard.
Recent events (1)
  • — Z (O) $0

1926.1052 B03

Other-than-serious 1 instance 4 exposed
Issued
Nov 25, 2024
Abate by
Dec 6, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.1052(b)(3): Treads for temporary stairway service were not installed the full width and/or depth of the stair:  (a) 301 Hamilton St. Allentown, PA, Stairway: On or about June 3, 2024, employees used a stairway that had 17 steps to access the second level, but each tread did not have the full depth of the stairs.
Recent events (1)
  • — Z (O) $0

1926.1052 C01 I

Other-than-serious 1 instance 4 exposed
Issued
Nov 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.1052(c)(1)(i):Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  (a) 301 Hamilton St. Allentown, PA, Stairway: On or about June 3, 2024, employees used a stairway that had 17-riser but was without at least one handrail, exposing employees to a slip/trip hazard.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347525974.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.