Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MACLEAN CURTIS LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MACLEAN CURTIS LLC. in 50 THIELMAN DRIVE, BUFFALO, NY 14206 (NAICS 332721). OSHA activity number 347527558.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Maclean Curtis LLC. — free Get an email when a new federal OSHA severe-injury report for Maclean Curtis LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
MACLEAN CURTIS LLC.
Site address
50 THIELMAN DRIVE
City
BUFFALO
State
NY
ZIP
14206
Mailing
50 THIELMAN DRIVE, BUFFALO, NY 14206
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332721
Employees
100
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 13, 2024
Penalty
Initial $4,662 · Current $3,497 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) On or about 06/05/2024 in the Tool Room, energy control procedures (lockout) were not used when employees were changing the grinding wheel. Exposing employees to caught-by hazards.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $3496.5
  • — Z (S) $4662

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 13, 2024
Abate by
Aug 29, 2024
Penalty
Initial $5,485 · Current $4,114 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) On or about 06/05/2024, throughout the establishment, the employer did not conduct periodic inspections of the Lockout/Tagout procedures for employees that perform servicing activities such as, but not limited to doing maintenance on Assembly machines  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $4113.75
  • — Z (S) $5485

1910.212 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 13, 2024
Penalty
Initial $4,662 · Current $3,497 Reduced
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible:  a) On or about 06/05/2024, in the 6R area, the PC Schutte machine did not have guards that were affixed to the machine to prevent bypassing, removing, or tampering. The side guard was left open while employees were running the machine exposing them to caught-by hazards.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $3496.5
  • — Z (S) $4662

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347527558.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.