Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GOLFERS FAMILY CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of GOLFERS FAMILY CORPORATION in 1531 PRESTON STREET, ROCKFORD, IL 61102 (NAICS 332811). OSHA activity number 347531139.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Golfers Family Corporation — free Get an email when a new federal OSHA severe-injury report for Golfers Family Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1531 PRESTON STREET
City
ROCKFORD
State
IL
ZIP
61102
Mailing
1531 PRESTON STREET, ROCKFORD, IL 61102
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332811
Employees
20
Ownership type
A

4 citations on file for this inspection.

1910.101 B

Serious Gravity 10 1 instance 17 exposed
Issued
Sep 27, 2024
Abate by
Oct 28, 2024
Penalty
Initial $6,452 · Current $3,226 Reduced

Hazardous substances P249X100

29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  (a) Dock area - On or about June 6, 2024, the employer failed to segregate propylene compressed gas cylinders from oxygen compressed gas cylinders, thereby exposing employees to fire and explosion hazards that may result in death.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $3226
  • — Z (S) $6452

1910.219 B01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Sep 27, 2024
Abate by
Oct 28, 2024
Penalty
Initial $4,610 · Current $0 Reduced
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv):   (a) Furnace area - On or about June 6, 2024, the employer failed to guard the flywheels of two floor mount exhaust fans which were mounted under the parts cooling rack thereby exposing employees to caught-in hazards that may result in amputation.   Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $4610

1910.305 B01 II

Serious Gravity 5 3 instances 1 exposed
Issued
Sep 27, 2024
Abate by
Oct 28, 2024
Penalty
Initial $3,687 · Current $1,844 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a) Furnace area - On or about June 6, 2024, the employer did not ensure that the panel board next to the cooling rack was effectively enclosed in that gaps were present between the dead front face and installed circuit breakers thereby exposing employees to fire hazards.  (b) Furnace area - On or about June 6, 2024, the employer did not ensure that the panel board next to the cooling rack was effectively enclosed in that a filler plate was not installed over an opening reserved for a circuit breaker thereby exposing employees to fire and shock hazards.    Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1844
  • — Z (S) $3687

1910.132 D02

Other-than-serious 1 instance 2 exposed
Issued
Sep 27, 2024
Abate by
Oct 28, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.132(d)(2):The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:  (a) Facility wide - On or about June 6, 2024, the employer did not complete a written certification of the personal protective equipment hazard assessment.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347531139.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.