Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MERCER GROUP INTERNATIONAL OF NEW JERSEY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MERCER GROUP INTERNATIONAL OF NEW JERSEY, INC. in 1519 CALHOUN STREET, TRENTON, NJ 08638 (NAICS 562920). OSHA activity number 347534331.

Watch Mercer Group International OF NEW Jersey, INC. — free Get an email when a new federal OSHA severe-injury report for Mercer Group International OF NEW Jersey, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1519 CALHOUN STREET
City
TRENTON
State
NJ
ZIP
08638
Mailing
1519 CALHOUN STREET, TRENTON, NJ 08638
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
562920
Employees
75
Ownership type
A

6 citations on file for this inspection.

1910.36 G02

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 10, 2024
Penalty
Initial $11,292 · Current $6,775 Reduced
29 CFR  1910.36(g)(2):Exit access was not at least 28 inches wide at all points:  a) MRF Building - C Line - Employees were exposed to emergency egress hazards in that the employer did not maintain 28 inches wide exit access at all points. Aisleways which lead to emergency exit routes were blocked with a permanently place debris chute and only offered approximately 7 inch wide exit access. This condition was observed on or about June 5, 2024.  NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $6775
  • — Z (S) $11292

1910.37 A03

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 10, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(3): Exit routes were not free and/or unobstructed, equipment was placed permanently within the exit route:  a) MRF Building - Transfer Station - C Line - Employees were exposed to emergency egress hazards in that the employer did not maintain that exit routes are unobstructed. Aisleways which lead to emergency exit routes were blocked with a permanently place debris chute. This condition was observed on or about June 5, 2024.  NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.101 B

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 10, 2024
Penalty
Initial $11,292 · Current $6,775 Reduced
29 CFR  1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders was not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6. Section 3.3.1 of the CGA Pamphlet P-1-1965 refers to storing cylinders in accordance with CGA and NFPA standards. The CGA Pamphlet P-1-1991 Section 3.7.4.1 states that "All compressed gas cylinders in service or in storage shall be secured to prevent from falling.":  a) Welding Shop - Employees are exposed to fire/explosion hazards in that the employer allows worker to use Oxygen and Acetylene torch set-up in a free standing position while in service and not secured to an approved cart or structure. This condition was observed on or about June 5, 2024.  NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $6775
  • — Z (S) $11292

1910.253 E03 II C 3

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 10, 2024
Penalty
Initial $4,839 · Current $2,905 Reduced
29 CFR  1910.253(e)(3)(ii)(C)(3): Flashback protection was not provided by an approved device that would prevent flame from passing into the fuel gas system:  a) Welding Shop - Employees are exposed to fire hazards in that the employer allows employees to operate the oxygen/acetylene torch set up without having a flashback arrestor in place. This condition was observed on or about June 5, 2024.  NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $2905
  • — Z (S) $4839

1910.303 B07 I

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 10, 2024
Penalty
Initial $11,292 · Current $6,775 Reduced
29 CFR  1910.303(b)(7)(i): Unused openings in boxes, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:  a) Welding Shop - The employer did not ensure that unused openings in the energized circuit breaker panel (120/240V) was effectively closed, the energized conductor (buss bar) was not guarded against accidental contact. Thus exposing the employees to electrocution hazards. This condition was observed on or about June 5, 2024.  NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $6775
  • — Z (S) $11292

1910.134 C02 I

Other-than-serious 1 instance 3 exposed
Issued
Sep 10, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Where the employer provided respirators for employees to use voluntarily, the employer did not provide the respirator user with the information contained in Appendix D to this section ("Information for Employees Using Respirators When Not Required Under the Standard"):  a) 1519 Calhoun St, Trenton, NJ - The employer provides employees with North N95 disposable particulate respirators to wear on site voluntarily and did not provide the users with the information contained in Appendix D ("Information for Employees Using Respirators When Not Required Under the Standard"), thus exposing employees to dermatitis. This condition was observed on or about June 5, 2024.  NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347534331.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.