Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J RODRIGUEZ REMODELING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J RODRIGUEZ REMODELING LLC in 123 W KNAPP ST., RICE LAKE, WI 54868 (NAICS 238160). OSHA activity number 347535288.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J Rodriguez Remodeling LLC — free Get an email when a new federal OSHA severe-injury report for J Rodriguez Remodeling LLC is published. One employer, no account, unsubscribe in one click.
Site address
123 W KNAPP ST.
City
RICE LAKE
State
WI
ZIP
54868
Mailing
1114 BUSH AVE., APT 2, SAINT PAUL, MN 55106
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 13, 2024
Abate by
Sep 27, 2024
Penalty
Initial $2,074 · Current $2,074
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  (a) Roof of residential home; On or about June 5, 2024, employees were allowed to operate pneumatic nail guns during roofing activities without wearing eye protection.
Recent events (1)
  • — Z (S) $2074

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 13, 2024
Abate by
Sep 27, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR 1926.501(b)(13):  Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    (a) Roof of residential home; On or about June 5, 2024, fall protection systems were not used during residential reroofing operations at heights ranging from 10 feet, 6 inches to more than 25 feet above the ground.
Recent events (1)
  • — Z (S) $4839

1926.503 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Sep 13, 2024
Abate by
Sep 27, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  (a) Roof of residential home; On or about June 5, 2024, and dates prior, fall hazard awareness and/or fall prevention training was not provided to employees before they performed roofing activities at heights ranging from 10 feet, 6 inches to more than 25 feet above the ground.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 3 instances 7 exposed
Issued
Sep 13, 2024
Abate by
Sep 27, 2024
Penalty
Initial $3,457 · Current $3,457
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   (a) Roof of residential home; On or about June 5, 2024, side rails of aluminum extension ladder setup at ground level to access an elevated work area on the lower back roof did not extend 3 feet past the upper landing.  (b) Roof of residential home; On or about June 5, 2024, side rails of aluminum extension ladder setup on the lower back roof to access an elevated work area on the upper main roof did not extend 3 feet past the upper landing.  (c) Roof of residential home; On or about June 5, 2024, side rails of an aluminum multi-ladder setup as a non-self-supporting ladder to access an elevated work area on the front porch roof did not extend 3 feet past the upper landing.
Recent events (1)
  • — Z (S) $3457

1926.1060 A

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 13, 2024
Abate by
Sep 27, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways:  (a) Roof of residential home; On or about June 5, 2024, training was not provided to inform employees how to properly setup, use, and inspect ladders before they used extension and multi-position type ladders to access elevated work areas as part of roofing operations.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347535288.