Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JOHNSON CONTROLS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JOHNSON CONTROLS INC. in 100 CUMBERLAND VALLEY AVENUE, WAYNESBORO, PA 17268 (NAICS 333415). OSHA activity number 347543076.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Johnson Controls INC. — free Get an email when a new federal OSHA severe-injury report for Johnson Controls INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 CUMBERLAND VALLEY AVENUE
City
WAYNESBORO
State
PA
ZIP
17268
Mailing
100 CUMBERLAND VALLEY AVENUE ATTN: CORY BURKHART, WAYNESBORO, PA 17268
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333415
Employees
350
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 5 instances 3 exposed
Issued
Dec 3, 2024
Abate by
Jan 6, 2025
Penalty
Initial $16,131 · Current $15,000 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards in the event of catastrophic equipment failure while performing pneumatic pressure tests on a bare screw compressor within a Screw Compressor Test Chamber:  a)	Compressor Assembly Building, Compressor Test Area Compressor Assembly Building, Compressor Test Area ? On or about June 11, 2024, employees performed a pneumatic pressure test of a bare screw compressor within a screw compressor test chamber when a combustion event within the test chamber unexpectedly and unforeseeably occurred.   Abatement certification and documentation required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $15000
  • — Z (S) $16131

1910.212 A02

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Dec 3, 2024
Abate by
Dec 30, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(2): Machine guard(s) on machines were so installed that they offered accident hazards in themselves:   a) Compressor Assembly Building, Compressor Test Area - The design and installation of the yellow sheet metal barrier located in front of the Screw Compressor Test Chamber's pressure relief ports exposed employees to struck-by hazards in the event of a catastrophic overpressurization event within the test chamber. Employees suffered serious injuries not limited to severe lacerations and bruising and fractured bones after being struck by the barrier after it blew off the test chamber as projectile towards them, on or about June 11, 2024.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.28 B15

Other-than-serious Gravity 1 1 instance 3 exposed
Issued
Dec 3, 2024
Abate by
Dec 30, 2024
Penalty
Initial $6,464 · Current $0 Reduced
29 CFR  1910.28(b)(15): Except as provided elsewhere in this section or by other subparts of this part, the employer did not ensure each employee on a walking-working surface 4 feet (1.2 m) or more above a lower level was protected from falling:  a) Compressor Assembly Building / Compressor Test Area - Employees were exposed to fall hazards into an approximate 5-foot deep water tank, on or about June 11, 2024.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (S) $6464

View Johnson Controls INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347543076.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.