Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: 412 HOME REMODELING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of 412 HOME REMODELING in 25 AND 27 SOUTH BRYANT AVENUE, BELLEVUE, PA 15202 (NAICS 238160). OSHA activity number 347543555.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch 412 Home Remodeling — free Get an email when a new federal OSHA severe-injury report for 412 Home Remodeling is published. One employer, no account, unsubscribe in one click.
Establishment
412 HOME REMODELING
Site address
25 AND 27 SOUTH BRYANT AVENUE
City
BELLEVUE
State
PA
ZIP
15202
Mailing
3508 HIGLAND AVENUE, FINLEYVILLE, PA 15332
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 27, 2024
Penalty
Initial $3,457 · Current $3,457
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provided for an alternative fall protection measure:   a) Job site, 25 and 27 South Bryant Street, Bellevue, PA: On or about June 11, 2024, during roofing activities, the employer did not ensure that all employees had and used appropriate fall protection systems/devices where exposed to fall hazards of up to at least 20 feet.
Recent events (1)
  • — Z (S) $3457

1926.1053 B01

Other-than-serious 1 instance 1 exposed
Issued
Jun 27, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access; or, when such an extension was not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that would not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder:   a) Job site, 25 and 27 South Bryant Street, Bellevue, PA: On or about June 11, 2024, during roofing activities, the employer did not ensure that the ladder used to get up/down from the roof was properly extended in that it only extended about 30 inches or so above the roof line.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347543555.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.