APPLETON, WI —
OSHA Inspection: AL DIX CONCRETE INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of AL DIX CONCRETE INC. in N LILAS DRIVE BETWEEN W COLLEGE AVENUE AND W COLLEGE SERVICE ROAD, APPLETON, WI 54914 (NAICS 238110). OSHA activity number 347549313.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AL DIX CONCRETE INC.
- Site address
- N LILAS DRIVE BETWEEN W COLLEGE AVENUE AND W COLLEGE SERVICE ROAD
- City
- APPLETON
- State
- WI
- ZIP
- 54914
- Mailing
- 401 GERTRUDE ST, KAUKAUNA, WI 54130
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 10
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.134 C01
- Issued
- Jul 25, 2024
- Abate by
- Sep 16, 2024
- Penalty
- Initial $8,067 · Current $4,034 Reduced
9000
General-duty citation text
29 CFR 1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer shall establish and implement a written respiratory protection program with worksite-specific procedures. The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use: (Construction Reference: 1926.103) On June 13, 2024, at a worksite located on N Lilas Drive between W College Avenue and W College Service Road in Appleton, WI; the employer did not implement their written respirator protection program when respiratory protection was necessary to protect the health of an employee who had been operating a dowel drilling rig for concrete. All provisions of 29 CFR 1910.134 (c) through (m) must be covered in a respiratory protection program. Key elements include, but are not limited to the following: 1) Medical clearances for respirator use 2) Fit testing 3) Employee training on respirator use, maintenance, care, and limitation 4) Recordkeeping 5) Program annual review
Recent events (2)
- — I (S) $4033.5
- — Z (S) $8067
1910.134 E01
- Issued
- Jul 25, 2024
- Abate by
- Sep 16, 2024
- Penalty
- Initial $0 · Current $0
9000
General-duty citation text
29 CFR 1910.134(e)(1): General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator: (Construction Reference: 1926.103) On June 13, 2024, at a worksite located on N Lilas Drive between W College Avenue and W College Service Road in Appleton, WI; the employer did not provide a medical evaluation to determine an employee's ability to use a half-face tight-fitting respirator when respiratory protection was necessary to protect the health of the employee who had been operating a dowel drilling rig for concrete.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Jul 25, 2024
- Abate by
- Sep 16, 2024
- Penalty
- Initial $0 · Current $0
9000
General-duty citation text
29 CFR 1910.134(f)(1): The employer shall ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph: (Construction Reference: 1926.103) On June 13, 2024, at a worksite located on N Lilas Drive between W College Avenue and W College Service Road in Appleton, WI; the employer did not ensure that an employee using a half-face tight-fitting respirator passed an appropriate QLFT or QNFT when respiratory protection was necessary to protect the health of the employee who had been operating a dowel drilling rig for concrete.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K
- Issued
- Jul 25, 2024
- Abate by
- Aug 23, 2024
- Penalty
- Initial $0 · Current $0
9000
General-duty citation text
29 CFR 1910.134(k): Training and information. This paragraph requires the employer to provide effective training to employees who are required to use respirators. The training must be comprehensive, understandable, and recur annually, and more often if necessary: (Construction Reference: 1926.103) On June 13, 2024, at a worksite located on N Lilas Drive between W College Avenue and W College Service Road in Appleton, WI; the employer did not provide training to each employee that was required to wear a half-face tight-fitting respirator when respiratory protection was necessary to protect the health of the employee who had been operating a dowel drilling rig for concrete. All provisions of 29 CFR 1910.134(k)(1) through (k)(6) shall be provided to employees wearing respirators. Key elements include, but are not limited to the following: 1) Reason for respirators use 2) Respirator limitations and capabilities 3) Effective respirator inspection and use 4) Procedures for maintenance, care and storage of respirators 5) Recognition of signs/symptoms that may limit respirator use 6) The requirements of the respiratory protection standard
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1153 I02 I C
- Issued
- Jul 25, 2024
- Abate by
- Aug 23, 2024
- Penalty
- Initial $8,067 · Current $4,034 Reduced
9000
General-duty citation text
29 CFR 1926.1153(i)(2)(i)(C): The employer shall ensure that each employee covered by this section can demonstrate knowledge and understanding of the specific measures the employer has implemented to protect employees from exposure to respirable crystalline silica, including engineering controls, work practices, and respirators to be used: On June 13, 2024, at a worksite located on N Lilas Drive between W College Avenue and W College Service Road in Appleton, WI; the employer did not ensure that an employee operating a dowel drilling rig for concrete could demonstrate knowledge and understanding of the specific engineering control and respiratory protection that was required to protect them from exposure to respirable crystalline silica while drilling into concrete.
Recent events (2)
- — I (S) $4033.5
- — Z (S) $8067
1926.1153 I02 I D
- Issued
- Jul 25, 2024
- Abate by
- Aug 16, 2024
- Penalty
- Initial $0 · Current $0
9000
General-duty citation text
29 CFR 1926.1153(i)(2)(i)(D): The employer shall ensure that each employee covered by this section can demonstrate knowledge and understanding of the contents of this section: On June 13, 2024, at a worksite located on N Lilas Drive between W College Avenue and W College Service Road in Appleton, WI; the employer did not ensure that an employee operating a dowel drilling rig for concrete could demonstrate knowledge and understanding of the contents of this section.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1153 C01
- Issued
- Jul 25, 2024
- Abate by
- Sep 16, 2024
- Penalty
- Initial $16,134 · Current $8,067 Reduced
9000
General-duty citation text
29 CFR 1926.1153(c)(1): Specified exposure control methods. For each employee engaged in a task identified on Table 1, the employer shall fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section: On June 13, 2024, at a worksite located on N Lilas Drive between W College Avenue and W College Service Road in Appleton, WI; the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, "(viii) Dowel drillings rig for concrete". The dowel drilling rig was not equipped with a shroud around the drill bit with a dust collection system. The employee operating the equipment was not fit tested for a respirator with an assigned protection factor (APF) of at least 10. The Al Dix Concrete Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1153(c)(1), which was contained in OSHA inspection number 1556082, citation number 1, item number 1a and was affirmed as a final order on January 6, 2022 with respect to a workplace located at 1210 Ceape Ave, Oshkosh, WI 54901.
Recent events (2)
- — I (R) $8067
- — Z (R) $16134
1926.1153 D02 I
- Issued
- Jul 25, 2024
- Abate by
- Sep 16, 2024
- Penalty
- Initial $0 · Current $0
9000
General-duty citation text
29 CFR 1926.1153(d)(2)(i): The employer shall assess the exposure of each employee who is or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section: On June 13, 2024, at a worksite located on N Lilas Drive between W College Avenue and W College Service Road in Appleton, WI; the employer did not assess the exposure level of an employee operating a dowel drilling rig for concrete and did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1. The Al Dix Concrete Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1153(d)(2)(i), which was contained in OSHA inspection number 1556082, citation number 1, item number 1b and was affirmed as a final order on January 6, 2022 with respect to a workplace located at 1210 Ceape Ave, Oshkosh, WI 54901.
Recent events (2)
- — I (R) $0
- — Z (R) $0
More inspections at AL DIX Concrete INC.
View AL DIX Concrete INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238110)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347549313.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.