OSHA Inspection: CEREBRAL BREWING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CEREBRAL BREWING, LLC in 1477 MONROE STREET, DENVER, CO 80206 (NAICS 312120). OSHA activity number 347550378.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cerebral Brewing, LLC — free Get an email when a new federal OSHA severe-injury report for Cerebral Brewing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1477 MONROE STREET
City
DENVER
State
CO
ZIP
80206
Mailing
1477 MONROE STREET, DENVER, CO 80206
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
312120
Employees
20
Ownership type
A

3 citations on file for this inspection.

1910.37 A03

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Oct 7, 2024
Penalty
Initial $3,496 · Current $0 Reduced
29 CFR  1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  a) 1477 Monroe Street DENVER, CO 80206 - Brewing area: On or about June 13, 2024 and at times prior, employees were exposed to entrapment hazards while working in and around areas where empty barrels/ racks were placed in the designated exit routes leaving a pathway that was restricted to approximately 19 inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3496

1910.157 E02

Other-than-serious 1 instance 20 exposed
Issued
Oct 7, 2024
Abate by
Nov 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:   (a)  1477 Monroe Street DENVER, CO 80206 - Brewing area: On or about April 15, 2024, and at times prior employees were exposed to fire and inhalation hazards from fire extinguishers not being visually inspected at least monthly to be fully charged and readily available for use.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.243 B02

Other-than-serious 1 instance 2 exposed
Issued
Oct 7, 2024
Abate by
Nov 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.243(b)(2):  Airhose and hose connections used for conducting compressed air to utilization equipment was not designed for the pressure and service to which they were subjected.  (a) 1477 Monroe Street DENVER, CO 80206 - Brewing area: On or about June 13, 2024 and at times prior, employees were exposed to struck-by hazards while utilizing the bottle capper in that it's airhose was not fit with proper connecting devices securing the hoses to the fittings.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Cerebral Brewing, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347550378.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.