PATERSON, NJ ·
OSHA Inspection: STARLITE WINDOW
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STARLITE WINDOW in 50 EAST 25TH STREET, PATERSON, NJ 07514 (NAICS 493110). OSHA activity number 347552119.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STARLITE WINDOW
- Site address
- 50 EAST 25TH STREET
- City
- PATERSON
- State
- NJ
- ZIP
- 07514
- Mailing
- 50 EAST 25TH STREET, PATERSON, NJ 07514
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 15
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.110 E04 III
- Issued
- Dec 6, 2024
- Penalty
- Initial $2,765 · Current $2,765
General-duty citation text
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating: a) Facility: Employee was operating a forklift with the removable fuel container not properly mounted in the index pin. The LPG container could rotate or slip while employee was operating the forklift, on or about 6/12/24.
Recent events (1)
- · Z (S) $2765
1910.178 L01 II
- Issued
- Dec 6, 2024
- Abate by
- Jan 27, 2025
- Penalty
- Initial $5,531 · Current $5,531
General-duty citation text
29 CFR 1910.178(l)(1)(ii):29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a power industrial truck: a) Facility: The employer did not ensure that each operator had successfully completed the training required, on or about 6/12/24.
Recent events (1)
- · Z (S) $5531
1910.213 D01
- Issued
- Dec 6, 2024
- Penalty
- Initial $6,452 · Current $6,452
General-duty citation text
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) Building Interior-shop: Employees were exposed to amputations while using a table saw that was not guarded by an automatically adjusting hood, on or about 6/12/24 b) Building Interior-shop: Employees were exposed to amputations while using a chop saw that was not guarded by an automatically adjusting hood, on or about 6/12/24
Recent events (1)
- · Z (S) $6452
1910.305 B01 II
- Issued
- Dec 6, 2024
- Penalty
- Initial $5,531 · Current $5,531
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Shop main electrical panel: Employees were expose to electrical shock while using a panel box that were missing a circuit braker, on or about 6/12/24.
Recent events (1)
- · Z (S) $5531
More inspections in this industry (NAICS 493110)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347552119.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.