OSHA Inspection: VERTEX AEROSPACE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VERTEX AEROSPACE in BUILDING 821 SOUTH LOOP ROAD, FORT IRWIN, CA 92310 (NAICS 493110). OSHA activity number 347555427.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vertex Aerospace — free Get an email when a new federal OSHA severe-injury report for Vertex Aerospace is published. One employer, no account, unsubscribe in one click.
Establishment
VERTEX AEROSPACE
Site address
BUILDING 821 SOUTH LOOP ROAD
City
FORT IRWIN
State
CA
ZIP
92310
Mailing
2424 WEST GARDEN OF THE GODS ROAD SUITE 300 BLDG E, COLORADO SPRINGS, CO 80919
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
3
Ownership type
A

2 citations on file for this inspection.

1910.178 L04 III

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Jul 15, 2024
Abate by
Aug 8, 2024
Penalty
Initial $5,288 · Current $2,908 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  Building 821:  On or about June 13, 2024, employees are exposed to struck-by hazards, in that a forklift evaluation had not been provided to employees using the Mitsubishi FG35K forklift to move supplies within the warehouse.
Recent events (2)
  • — I (O) $2908
  • — Z (S) $5288

1910.157 E03

Deleted Other-than-serious 1 instance 3 exposed
Issued
Jul 15, 2024
Abate by
Aug 8, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request:  On or about June 13, 2024, the employer did not ensure that annual maintenance checks of portable fire extinguishers located throughout the facility were completed as required. Records with the name of the individual(s) who conducted the inspection and along with the date the inspection was completed were not retained and/or made available for review by a representative of the Secretary of Laborer.