FORT IRWIN, CA —
OSHA Inspection: VERTEX AEROSPACE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VERTEX AEROSPACE in BUILDING 821 SOUTH LOOP ROAD, FORT IRWIN, CA 92310 (NAICS 493110). OSHA activity number 347555427.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VERTEX AEROSPACE
- Site address
- BUILDING 821 SOUTH LOOP ROAD
- City
- FORT IRWIN
- State
- CA
- ZIP
- 92310
- Mailing
- 2424 WEST GARDEN OF THE GODS ROAD SUITE 300 BLDG E, COLORADO SPRINGS, CO 80919
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.178 L04 III
- Issued
- Jul 15, 2024
- Abate by
- Aug 8, 2024
- Penalty
- Initial $5,288 · Current $2,908 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: Building 821: On or about June 13, 2024, employees are exposed to struck-by hazards, in that a forklift evaluation had not been provided to employees using the Mitsubishi FG35K forklift to move supplies within the warehouse.
Recent events (2)
- — I (O) $2908
- — Z (S) $5288
1910.157 E03
- Issued
- Jul 15, 2024
- Abate by
- Aug 8, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request: On or about June 13, 2024, the employer did not ensure that annual maintenance checks of portable fire extinguishers located throughout the facility were completed as required. Records with the name of the individual(s) who conducted the inspection and along with the date the inspection was completed were not retained and/or made available for review by a representative of the Secretary of Laborer.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 493110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347555427.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.