Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LEAMAN CONTAINER INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LEAMAN CONTAINER INC. in 5701 EAST ROSEDALE STREET, FORT WORTH, TX 76112 (NAICS 322211). OSHA activity number 347556763.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Leaman Container INC. — free Get an email when a new federal OSHA severe-injury report for Leaman Container INC. is published. One employer, no account, unsubscribe in one click.
Site address
5701 EAST ROSEDALE STREET
City
FORT WORTH
State
TX
ZIP
76112
Mailing
5701 EAST ROSEDALE STREET, FORT WORTH, TX 76112
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322211
Employees
52
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 35 exposed
Issued
Sep 17, 2024
Abate by
Oct 8, 2024
Penalty
Initial $6,857 · Current $4,114 Reduced
29 CFR  1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  On or about June 17, 2024, and at times prior thereto and at times thereafter, the energy control procedures for equipment did not outline the scope, purpose, authorization, rules, and techniques for the control hazardous energy sources on the equipment listed below:   Instance a) Unitizer; Instance b) Slitter; Instance c) Bailer; Instance d) Shredder; Instance e) Eccentric; Instance f) Ban Saw; Instance g) Rotary Slotter; Instance h) Post Fold Gluer; Instance i) Stitcher; Instance j) Gluer; Instance k) Rotary Die Cutter and; Instance l) Flexo Folder Gluer
Recent events (2)
  • — I (S) $4114.2
  • — Z (S) $6857

1910.147 C07 I A

Serious Gravity 10 1 instance 35 exposed
Issued
Sep 17, 2024
Abate by
Oct 8, 2024
Penalty
Initial $11,292 · Current $6,775 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  On or about June 17, 2024, and at times prior thereto, affected employees who performed the work of authorized employees did not receive training in the recognition of hazardous energy sources, the type and magnitude of the energy associated with the equipment they serviced and/or maintained.
Recent events (2)
  • — I (S) $6775.2
  • — Z (S) $11292

View Leaman Container INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347556763.