Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A.F.K. CORP.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of A.F.K. CORP. in 300 PACIFIC STREET, RIPON, WI 54971 (NAICS 331511). OSHA activity number 347560138.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A.F.K. Corp. — free Get an email when a new federal OSHA severe-injury report for A.F.K. Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
A.F.K. CORP.
Site address
300 PACIFIC STREET
City
RIPON
State
WI
ZIP
54971
Mailing
300 PACIFIC STREET, RIPON, WI 54971
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
65
Ownership type
A

3 citations on file for this inspection.

1910.147 D

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Sep 25, 2024
Abate by
Oct 24, 2024
Penalty
Initial $11,292 · Current $0 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On or about June 12, 2024, at the facility located at 300 Pacific Street, Ripon, Wisconsin; an employee was exposed to machine hazards associated with moving parts when they engaged in servicing and maintenance activities on the B&P Mold handler (MH-6).  The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to clean weights and jackets.  The machine was not deenrgized prior to employees engaging in service/maintenance activities.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11292

1910.147 C04 II

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 25, 2024
Penalty
Initial $0 · Current $6,775
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the requirements of section (c)(4)(ii)(A)-(c)(4)(ii)(D) of this standard.  On or about June 12, 2024, at the facility located at 300 Pacific Street, Ripon, Wisconsin; the hazardous energy control procedure for the B&P Mold handler (MH-6) did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance. Specifically, the procedure did not account for the verification of isolation for energy sources such as, but not limited to, pneumatic and hydraulic.
Recent events (2)
  • — I (S) $6775.2
  • — Z (S) $0

1910.147 C06 II

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 25, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.  On or about June 12, 2024, at the facility located at 300 Pacific Street, Ripon, Wisconsin; the employer's periodic inspection certification did not identify the machine or equipment on which the energy control procedure was utilized.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View A.F.K. Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347560138.