GRAND BAY, AL —
OSHA Inspection: FIBER GLASS SYSTEMS, LP
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of FIBER GLASS SYSTEMS, LP in 12050 INTERCHANGE DRIVE, GRAND BAY, AL 36541 (NAICS 332996). OSHA activity number 347589103.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FIBER GLASS SYSTEMS, LP
- Site address
- 12050 INTERCHANGE DRIVE
- City
- GRAND BAY
- State
- AL
- ZIP
- 36541
- Mailing
- 12050 INTERCHANGE DRIVE, GRAND BAY, AL 36541
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332996
- Employees
- 100
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.1200 E01
- Issued
- Oct 7, 2024
- Abate by
- Nov 5, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program that included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a) Facility wide; On or about June 18, 2024, and at times prior thereto the employer did not have a written hazard communication program detailing the hazards of chemicals such as but not limited to Methyl Ethyl Ketone Peroxide (MEKP), fiber glass, and Styrene used in the facility
Recent events (1)
- — Z (O) $0
1910.1200 F10
- Issued
- Oct 7, 2024
- Abate by
- Nov 5, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(10): The employer did not ensure that workplace labels or other forms of warnings were legible, in English and prominently displaced on the container or readily available in the work area throughout each work shift. a) Assembly Area; On or about July 8, 2024, and at times prior thereto the employer did not ensure containers of chemicals such as but not limited to Methyl Ethyl Ketone Peroxide (MEKP) used in the facility had legible labels or other forms of warning.
Recent events (1)
- — Z (O) $0
More inspections at Fiber Glass Systems, LP
View Fiber Glass Systems, LP's full OSHA safety record →
More inspections in this industry (NAICS 332996)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347589103.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.