OSHA Inspection: MAJESTIC STEEL USA, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MAJESTIC STEEL USA, INC. in 9302 LEY ROAD, HOUSTON, TX 77078 (NAICS 423510). OSHA activity number 347592248.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Majestic Steel USA, INC. — free Get an email when a new federal OSHA severe-injury report for Majestic Steel USA, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9302 LEY ROAD
City
HOUSTON
State
TX
ZIP
77078
Mailing
9302 LEY ROAD, HOUSTON, TX 77078
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423510
Employees
30
Ownership type
A

5 citations on file for this inspection.

1910.146 C05 II C

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Nov 15, 2024
Abate by
Jan 6, 2025
Penalty
Initial $16,131 · Current $16,131
29 CFR  1910.146(c)(5)(ii)(C):Employees entered into permit spaces that met the conditions set forth in 29 CFR 1910.146(c)(5)(i) but before an employee entered the space, the internal atmosphere was not tested with a calibrated direct-reading instrument.  On or about July 1, 2024  and times before,  at the work site,  where maintenance employees entered into permit required confined spaces without testing the internal atmosphere with a calibrated monitor.
Recent events (3)
  • — F (O) $16131
  • — C (S) $16131
  • — Z (S) $16131

1910.146 C07 I

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 15, 2024
Abate by
Jan 6, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.146(c)(7)(i):If the permit space poses no actual or potential atmospheric hazards and if all hazards within the space are eliminated without entry into the space, the permit space may be reclassified as a non-permit confined space for as long as the non-atmospheric hazards remain eliminated.  On or about July 1, 2024,  the employer did not determine whether the permit confined space had actual or potential atmospheric hazards within the space had been eliminated and reclassified the area as a non-permit confined space.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.146 D09

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 15, 2024
Abate by
Jan 6, 2025
Penalty
Initial $16,131 · Current $0 Reduced
29 CFR  1910.146(d)(9):Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces to rescue.  On or about July 1, 2024,  at the jobsite,  where maintenance employees were entering permit required confined spaces without the employer developing and implementing procedures for summoning rescue and emergency services .
Recent events (3)
  • — F (S) $0
  • — C (S) $16131
  • — Z (S) $16131

1910.146 F11

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 15, 2024
Abate by
Jan 6, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.146(f)(11):The entry permit that authorizes entry to a permit space did not identify the rescue and emergency services that can be summoned and the means for summoning those services.  On or about July 1, 2024 and times prior to, at the work site where maintenance employees entered permit required confined space  with entry permit that did not identify the rescue and emergency services to be summoned and the means for summoning those services.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.146 K03 II

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 15, 2024
Abate by
Jan 6, 2025
Penalty
Initial $16,131 · Current $0 Reduced
29 CFR 1910.146(k)(3)(ii): Each authorized entrant did not ensure the other end of the retrieval line was attached to a mechanical device or fixed point outside the permit space in such a manner that rescue could begin as soon as the rescuer is aware that rescue is necessary.   On or about July 1, 2024, at the work site where authorized maintenance employees entered the RBI/ Pit (Permit defined Confined Space) without a retrieval line attached to a mechanical device or fixed point outside the space for emergency retrieval.
Recent events (3)
  • — F (S) $0
  • — C (S) $16131
  • — Z (S) $16131

View Majestic Steel USA, INC.'s full OSHA safety record →