Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AQUA MANAGEMENT LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AQUA MANAGEMENT LLC in 980 PORTLAND ROAD, SACO, ME 04072 (NAICS 713110). OSHA activity number 347606329.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aqua Management LLC — free Get an email when a new federal OSHA severe-injury report for Aqua Management LLC is published. One employer, no account, unsubscribe in one click.
Establishment
AQUA MANAGEMENT LLC
Site address
980 PORTLAND ROAD
City
SACO
State
ME
ZIP
04072
Mailing
1 TUNIS AVE, OLD ORCHARD BEACH, ME 04064
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
713110
Employees
120
Ownership type
A

17 citations on file for this inspection.

1910.23 B08

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 25, 2024
Abate by
Aug 20, 2024
Penalty
Initial $8,296 · Current $4,148 Reduced
29 CFR 1910.23(b)(8):  The employer did not ensure that ladders are used only for the purposes for which they were designed:  Wave Pool Pump Pit 1 - Employees used the top and top step of a six-foot wooden stepladder to access a pump pit.
Recent events (2)
  • — I (S) $4148
  • — Z (S) $8296

1910.23 C11

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 25, 2024
Abate by
Sep 11, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(11):  The employer did not ensure that portable ladders used to gain access to an upper landing surface had side rails that extend at least 3 feet (0.9 m) above the upper landing surface:  Wave Pool Pump Pit 1 - Employees used a six-foot wooden stepladder to access and egress an eight-foot-deep pump pit.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.28 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 25, 2024
Abate by
Aug 20, 2024
Penalty
Initial $10,372 · Current $5,186 Reduced
29 CFR 1910.28(b)(1)(i):  The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):  Wave Pool Pump Pit 1 - Employees working eight feet above the pump pit were not protected from falling.
Recent events (2)
  • — I (S) $5186
  • — Z (S) $10372

1910.146 C01

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 25, 2024
Abate by
Aug 20, 2024
Penalty
Initial $14,518 · Current $7,259 Reduced
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:  Establishment - Employer failed to identify the wave pool pump pits as permit required confined space resulting in an employee losing consciousness from chlorine exposure when entering the confined space without taking precautions.
Recent events (2)
  • — I (S) $7259
  • — Z (S) $14518

1910.146 C02

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 25, 2024
Abate by
Aug 20, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:  Wave Pool Pump Pit 1 - The employer did not post a danger/confined sign in the vicinity of the pump pit.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 C04

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 25, 2024
Abate by
Sep 11, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:  Establishment - Employer required employees to enter the pump pit daily without developing or implementing a permit space entry program.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 G02 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 25, 2024
Abate by
Aug 20, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.146(g)(2)(i): The employer did not provide training to each affected employee before the employee was first assigned duties under 29 CFR 1910.146, Permit-required confined spaces:  Establishment - Employer required two employees to routinely access a permit required confined space without providing training.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 2 instances 126 exposed
Issued
Jul 25, 2024
Abate by
Aug 20, 2024
Penalty
Initial $10,372 · Current $5,186 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  Covers were not provided, in the following instances:       a) Office Area - One wall mounted outlet did not have a cover/faceplate.      b) Chlorine Tank Room - A wall mounted outlet/switch did not a cover/faceplate.
Recent events (2)
  • — I (S) $5186
  • — Z (S) $10372

1910.305 G01 IV A

Other-than-serious Gravity 1 1 instance 126 exposed
Issued
Jul 25, 2024
Penalty
Initial $6,222 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  Wave Pool Sump - The sump pump was powered by an extension cord run from the mechanical space, over six months ago.
Recent events (2)
  • — I (O) $0
  • — Z (S) $6222

1910.305 G01 IV C

Serious Gravity 1 1 instance 126 exposed
Issued
Jul 25, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(C):  Flexible cords were run through doorways, windows, or similar openings when they were not specifically permitted.  Wave Pool - Employer powered a sump pump with an extension cord run under a metal door.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 10 1 instance 10 exposed
Issued
Jul 25, 2024
Abate by
Sep 11, 2024
Penalty
Initial $14,518 · Current $7,259 Reduced
29 CFR 1910.1200(e)(1):  The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  Establishment - The employer did not develop a written hazard communication program for employees exposed to hazardous chemicals, such as sodium hypochlorite solution (pool chlorine).
Recent events (2)
  • — I (S) $7259
  • — Z (S) $14518

1910.1200 F06 II

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 25, 2024
Abate by
Aug 20, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:   Chlorine Storage Room - Two 1,600-gallon tanks of sodium hypochlorite solution (pool chlorine) were not properly labeled.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 10 1 instance 10 exposed
Issued
Jul 25, 2024
Abate by
Oct 2, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  Establishment - Employees were not provided effective information or training regarding the sections of a safety data sheet, labeling requirements, and pictograms prior to working with hazardous chemicals, such as such as sodium hypochlorite solution (pool chlorine).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.29 A

Other-than-serious 1 instance 120 exposed
Issued
Jul 25, 2024
Abate by
Sep 11, 2024
Penalty
Initial $2,074 · Current $1,037 Reduced
29 CFR 1904.29(a):  The employer did not use an OSHA 300, 301 and 300A Form or equivalent.  Establishment - The employer did not record employee injuries on the OSHA 300, 301 and 300A Form or equivalent.
Recent events (2)
  • — I (O) $1037
  • — Z (O) $2074

1910.132 D02

Other-than-serious 1 instance 126 exposed
Issued
Jul 25, 2024
Abate by
Aug 13, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:  Establishment - Employer did not complete a written certification verifying a workplace assessment for personal protective equipment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 2 instances 126 exposed
Issued
Jul 25, 2024
Abate by
Aug 20, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  Extinguishers were not inspected in the following instances:       a) Office Area - Drychem fire extinguisher was not inspected at least monthly.      b) Chlorine Tank Room - Water spray extinguisher was not inspected at least monthly.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.304 B03 II C 3

Other-than-serious 1 instance 2 exposed
Issued
Jul 25, 2024
Abate by
Aug 13, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(3)(ii)(C)(3):  Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug found damaged or defective was used before being repaired:  Liquid Chlorine Pump - The strain relief device, on a shop fabricated cord for the chlorine pump, was damaged and broken.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347606329.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.