Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPARTMENT OF INTERIOR - U.S. FISH AND WILDLIFE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPARTMENT OF INTERIOR - U.S. FISH AND WILDLIFE in 1624 HOOD-FRANKLIN ROAD, ELK GROVE, CA 95757 (NAICS 921190). OSHA activity number 347615890.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of Interior - U.S. Fish and Wildlife — free Get an email when a new federal OSHA severe-injury report for U.S. Department of Interior - U.S. Fish and Wildlife is published. One employer, no account, unsubscribe in one click.
Site address
1624 HOOD-FRANKLIN ROAD
City
ELK GROVE
State
CA
ZIP
95757
Mailing
1624 HOOD-FRANKLIN ROAD, ELK GROVE, CA 95757
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
921190
Employees
5
Ownership type
D

2 citations on file for this inspection.

1910.253 B04 III

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Aug 7, 2024
Abate by
Sep 3, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:   Facility Maintenance Building: On or before 07/09/2024 Acetylene and oxygen cylinders were stored near each other and were not separated the required distance of 20 feet. This condition potentially exposed employee(s) to fire hazard(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Other-than-serious 1 instance 1 exposed
Issued
Aug 7, 2024
Abate by
Sep 3, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.  Facility Maintenance Building: On or before 07/09/2024 the air used for cleaning was not reduced to less that 30 PSI.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View U.S. Department of Interior - U.S. Fish and Wildlife's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347615890.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.