DELAWARE, OH —
OSHA Inspection: ISMAEL NAVA RUIZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ISMAEL NAVA RUIZ in 43 LIPPAZON WAY, DELAWARE, OH 43015 (NAICS 238160). OSHA activity number 347618431.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ISMAEL NAVA RUIZ
- Site address
- 43 LIPPAZON WAY
- City
- DELAWARE
- State
- OH
- ZIP
- 43015
- Mailing
- 713 EDENDALE COURT, COLUMBUS, OH 43207
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Oct 3, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $4,839 · Current $4,839
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. a. Located at 33-43 Lippazon Way, Delaware, OH 43015: On or about July 15, 2024, employees performing roofing work in a residential subdivision consisting of condos and townhomes were exposed to fall hazards of approximately 16' as they walked and worked on under-construction roofs without fall protection or prevention systems or equipment.
Recent events (1)
- — Z (S) $4839
1926.1053 B01
- Issued
- Oct 3, 2024
- Abate by
- Oct 23, 2024
- Penalty
- Initial $3,457 · Current $3,457
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. a. Located at 33-43 Lippazon Way, Delaware, OH 43015: On or about July 15, 2024, employees performing roofing work in a residential subdivision consisting of condos and townhomes were exposed to fall hazards of approximately 16' as they used a portable extension ladder to access the landing surface of the under-construction roof. The ladder's side rails did not extend at least 3' past the upper landing surface.