WESTMONT, IL ·
OSHA Inspection: MANUEL SOLIS AGUILAR DBA MANUEL SOLIS AGUILAR
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MANUEL SOLIS AGUILAR DBA MANUEL SOLIS AGUILAR in 6220 FAIRMONT, WESTMONT, IL 60559 (NAICS 238160). OSHA activity number 347632184.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MANUEL SOLIS AGUILAR DBA MANUEL SOLIS AGUILAR
- Site address
- 6220 FAIRMONT
- City
- WESTMONT
- State
- IL
- ZIP
- 60559
- Mailing
- 1865 N. GREEN LANE N, PALATINE, IL 60074
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Sep 26, 2024
- Abate by
- Oct 18, 2024
- Penalty
- Initial $2,765 · Current $2,765
General-duty citation text
29 CFR 1926.102(a)(1):The employer did not ensure that each affected employee use appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors or potentially injurious light radiation. On or about July 17, 2024, employees engaged in residential roofing operations were exposed to eye injury hazards while operating pneumatic nail guns without eye protection. Employer did not ensure that employees that were engaged in roofing activities utilizing pneumatic guns were utilizing safety glasses. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (1)
- · Z (S) $2765
1926.501 B13
- Issued
- Sep 26, 2024
- Abate by
- Oct 18, 2024
- Penalty
- Initial $4,839 · Current $4,839
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. On or about July 17, 2024, Employees were exposed to fall hazards in approximately 8-18 feet while engaged in residential roofing activities. Fall protection was not being utilized while employees were installing new roofing. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(c).
Recent events (1)
- · Z (S) $4839
1926.1053 B01
- Issued
- Sep 26, 2024
- Abate by
- Oct 18, 2024
- Penalty
- Initial $2,765 · Current $2,765
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grab rail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about July 17, 2024, the portable ladder used to access the roof level did not extend at least three (3') feet above the upper landing surface, thereby exposing employees to fall hazard in approximately 10 feet. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (1)
- · Z (S) $2765
1926.1053 B04
- Issued
- Sep 26, 2024
- Abate by
- Oct 18, 2024
- Penalty
- Initial $2,074 · Current $2,074
General-duty citation text
29 CFR 1926.1053(b)(4):Ladder(s) shall be used only for the purpose for which they were designed: On or about July 17,2024 , employees were observed utilizing a laddervator, which is designed for hoisting material only, to access/descend the house roof. This exposed employees to falls up to 18 feet to the ground below. No abatement certification or documentation is required for this item.
Recent events (1)
- · Z (S) $2074
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347632184.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.