BROOKLYN, NY —
OSHA Inspection: THE 1010 CONSTRUCTION GROUP LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of THE 1010 CONSTRUCTION GROUP LLC in 1266 50TH STREET, BROOKLYN, NY 11219 (NAICS 238990). OSHA activity number 347632473.
Where did this inspection happen?
- Establishment
- THE 1010 CONSTRUCTION GROUP LLC
- Site address
- 1266 50TH STREET
- City
- BROOKLYN
- State
- NY
- ZIP
- 11219
- Mailing
- 27 SUNRISE DRIVE, MONSEY, NY 10952
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 1
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.651 I01
- Issued
- Abate by
- Penalty
- Initial $4839.00 · Current $4839.00
General-duty citation text
29 CFR 1926.651(i)(1): Where the stability of adjoining buildings, walls, or other structures was endangered by excavation operations, support systems such as shoring, bracing or underpinning was not provided to ensure the stability of such structures for the protection of employees. Location: 1266 50th Street, Brooklyn, NY 11219 On or about: February 2, 2024 (a) The employer did not ensure the stability of adjoining walls and structures were not endangered by excavation operations; the employer did not ensure bracing, shoring, or support systems were used while soil from was being removed from the basement.
Recent events (2)
- — C (S) $4839
- — Z (S) $4839
1926.754 A
- Issued
- Abate by
- Penalty
- Initial $4839.00 · Current $4839.00
General-duty citation text
29 CFR 1926.754(a): Structural stability shall be maintained at all times during the erection process. Location: 1266 50th Street, Brooklyn, NY 11219 On or about: February 2, 2024 (a) The employer did not ensure that structural stability was maintained at all times; structural stability was adversely affected following the removal of the support structures such as existing walls.
Recent events (2)
- — C (S) $4839
- — Z (S) $4839
1926.754 E06 I
- Issued
- Abate by
- Penalty
- Initial $4839.00 · Current $4839.00
General-duty citation text
29 CFR 1926.754(e)(6)(i): A derrick floor shall be fully decked and/or planked and the steel member connections completed to support the intended floor loading. Location: 1266 50th Street, Brooklyn, NY 11219 On or about: February 2, 2024 (a) The employer did not ensure that the 1st floor's steel member connections were completed to support the intended floor loading; materials such as steel joists were placed on the 1st floor which collapsed into the basement level.
Recent events (2)
- — C (S) $4839
- — Z (S) $4839
More inspections in this industry (NAICS 238990)
NEW YORK, NY—2026-07-09
PALM INDUSTRIES LLC
NEW YORK, NY—2026-07-09
PALM INDUSTRIES LLC
EL PASO, TX—2026-07-09
RM CRANE & RIGGING LLC.
LAKEWOOD, WA—2026-07-08
WA317992018 - HARMON INC DBA HARMON SERVICE GLAZING INC
VICTOR, NY—2026-07-08
DIMARCO CONSTRUCTORS
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347632473.