Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MARBLE CONCEPTS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARBLE CONCEPTS LLC in 860 PENNSYLVANIA BLVD, FEASTERVILLE TREVOSE, PA 19053 (NAICS 327991). OSHA activity number 347635161.

Watch Marble Concepts LLC — free Get an email when a new federal OSHA severe-injury report for Marble Concepts LLC is published. One employer, no account, unsubscribe in one click.
Establishment
MARBLE CONCEPTS LLC
Site address
860 PENNSYLVANIA BLVD
City
FEASTERVILLE TREVOSE
State
PA
ZIP
19053
Mailing
860 PENNSYLVANIA BLVD, FEASTERVILLE TREVOSE, PA 19053
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
18
Ownership type
A

6 citations on file for this inspection.

1910.134 C01

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2765.00 · Current $0.00 Reduced
29 CFR  1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  (a) 860 Pennsylvania Blvd., Feasterville Trevose Pa., 19053- On or about July 23, 2024, Polish and Fabrication area, the employer did not have a written respiratory protection program for employees required to wear a 3M half face respirator during polishing marble, granite, quartz and quartzite stone countertops, exposing employees to a respirator hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2765

1910.134 F02

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $1000.00
29 CFR  1910.134(f)(2):Employee(s) using tight-fitting facepiece respirators were not fit-tested prior to initial use of the respirator or annually refitted:  (a) 860 Pennsylvania Blvd., Feasterville Trevose Pa., 19053- On or about July 23, 2024, Polish and Fabrication area, employee(s) in the Polish and Fabrication area were required to wear 3M half-face respirators to protect from inhalation hazards. The employer did not provide a fit-test prior to initial use of the respirator.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $0

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator:  (a) 860 Pennsylvania Blvd., Feasterville Trevose Pa., 19053- On or about July 23, 2024, Polish and Fabrication area, the employer did not provide a medical evaluation for the employee(s) required to wear a half-mask respirator during polishing of marble, granite, quartz and quartzite stone countertops, exposing employee(s) to a respiratory hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1053 D03 I

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $4610.00 · Current $1950.00 Reduced
29 CFR  1910.1053(d)(3)(i): The employer did not perform initial monitoring to assess the 8-hour TWA exposure for each employee on the basis of one or more personal breathing zone air samples that reflect the exposures of employees on each shift, for each job classification, in each work area:  a) 860 Pennsylvania Blvd, Feasterville-Trevose, PA 19053, Fabrication floor - On or about July 23, 2024 the employer did not establish and implement a written exposure control plan addressing respirable crystalline silica in the workplace in accordance with this section.
Recent events (2)
  • — I (S) $1950
  • — Z (S) $4610

1910.1053 F02 I

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1053(f)(2)(i):The employer did not establish and implement a written exposure control plan:  a) 860 Pennsylvania Blvd, Feasterville-Trevose, PA 19053 Facility - On or about July 23, 2024 the employer did not establish and implement a written exposure control plan addressing respirable crystalline silica in the workplace in accordance with this section.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 Q06

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.178(q)(6):Industrial trucks shall not be altered so that the relative positions of the various parts are different from what they were when originally received from the manufacturer, nor shall they be altered either by the addition of extra parts not provided by the manufacturer or by the elimination of any parts, except as provided in paragraph (q)(12) of this section. Additional counterweighting of fork trucks shall not be done unless approved by the truck manufacturer:  (a) 860 Pennsylvania Blvd., Feasterville Trevose Pa., 19053- On or about July 23, 2024, Polish and Fabrication area, a Doosan Pro5 orange in color forklift - Model 630p-5, serial number FGADC-1790-02422 rear flashing light covered with cardboard. The flashing light is a warning device to alert pedestrians and other personnel of forklift activity.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347635161.