Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUARRIES DIRECT INTERNATIONAL, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of QUARRIES DIRECT INTERNATIONAL, LLC in 12955 EMMETT RD., HOUSTON, TX 77041 (NAICS 493190). OSHA activity number 347641623.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quarries Direct International, LLC — free Get an email when a new federal OSHA severe-injury report for Quarries Direct International, LLC is published. One employer, no account, unsubscribe in one click.
Site address
12955 EMMETT RD.
City
HOUSTON
State
TX
ZIP
77041
Mailing
5800 CENTRALCREST ST., HOUSTON, TX 77092
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493190
Employees
21
Ownership type
A

10 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 21 exposed
Issued
Nov 5, 2024
Penalty
Initial $8,067 · Current $6,454 Reduced
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):  On or about July 25, 2024, at the warehouse where an employee was exposed to unprotected sides of more than four feet as he was working from an order picker without fall protection utilized.
Recent events (2)
  • — I (S) $6453.6
  • — Z (S) $8067

1910.30 A01

Serious Gravity 5 1 instance 21 exposed
Issued
Nov 5, 2024
Penalty
Initial $8,067 · Current $0 Reduced
29 CFR 1910.30(a)(1):The employer did not provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart before any employee is exposed to a fall hazard. And/or the employer did not ensure employees are trained in the requirements of this paragraph on or before May 17, 2017.  On or about July 25, 2024, at the warehouse where an employee was exposed to a fall hazard as he were working from an order picker and not trained to utilize fall protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8067

1910.212 A01

Serious Gravity 5 1 instance 21 exposed
Issued
Nov 5, 2024
Abate by
Nov 20, 2024
Penalty
Initial $8,067 · Current $6,454 Reduced
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about July 25, 2024, at the sample area of warehouse employees were utilizing a Ryobi miter saw which had a non-functioning - broken blade guard.
Recent events (2)
  • — I (S) $6453.6
  • — Z (S) $8067

1910.303 B01

Serious Gravity 5 1 instance 21 exposed
Issued
Nov 5, 2024
Abate by
Nov 13, 2024
Penalty
Initial $8,067 · Current $6,454 Reduced
29 CFR  1910.303(b)(1):Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  On or about July 25, 2024, at the bay door of warehouse employees were utilizing a forklift charging station to charge forklifts and was exposed to accumulated water on the floor and table from roof water leaks and incoming rainwater.
Recent events (2)
  • — I (S) $6453.6
  • — Z (S) $8067

1910.304 F01 IV

Serious Gravity 5 1 instance 21 exposed
Issued
Nov 5, 2024
Penalty
Initial $8,067 · Current $0 Reduced
29 CFR  1910.304(f)(1)(iv):Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:  On or about July 25, 2024, at the back wall of warehouse there was an electrical breaker box and knife switch blocked by pallets of product and equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8067

1910.305 B01 II

Serious Gravity 5 1 instance 21 exposed
Issued
Nov 5, 2024
Penalty
Initial $8,067 · Current $0 Reduced
29 CFR 1910.303(g)(2)(i):Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  On or about July 25, 2024, at the back wall of the warehouse there was an electrical breaker box that did not have its cover in place while employees were accessing it.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8067

1910.1200 G01

Serious Gravity 5 1 instance 21 exposed
Issued
Nov 5, 2024
Abate by
Nov 13, 2024
Penalty
Initial $6,453 · Current $5,162 Reduced
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use.  On or about July 25, 2024, at the warehouse the employer did not have safety data sheets for chemicals such as propane, gasoline and battery fluid.
Recent events (2)
  • — I (S) $5162.4
  • — Z (S) $6453

1904.40 A

Other-than-serious 1 instance 21 exposed
Issued
Nov 5, 2024
Abate by
Nov 12, 2024
Penalty
Initial $1,613 · Current $1,290 Reduced
29 CFR  1904.40(a):The employer did not provide an authorized government representative the records within the four business hours.  On or about July 25, 2024, at the warehouse the employer did not provide OSHA logs to the compliance officer within four hours.
Recent events (2)
  • — I (O) $1290.4
  • — Z (O) $1613

1910.37 B02

Other-than-serious 1 instance 21 exposed
Issued
Nov 5, 2024
Abate by
Nov 12, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(2):Each exit was not clearly visible and marked by a sign reading "Exit":  On or about July 25, 2024, at the sample area of warehouse there was an exit door that did not have an exit sign.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 21 exposed
Issued
Nov 5, 2024
Abate by
Nov 13, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(2):Hose used in lieu of Class A portable fire extinguishers were not visually inspected at least monthly:  On or about July 25, 2024, throughout the warehouse fire extinguishers were not inspected monthly.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Quarries Direct International, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347641623.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.