HASTINGS, NE —
OSHA Inspection: NEBRASKA COLD STORAGE, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NEBRASKA COLD STORAGE, LLC in 600 EAST 39TH STREET, HASTINGS, NE 68901 (NAICS 493120). OSHA activity number 347645004.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEBRASKA COLD STORAGE, LLC
- Site address
- 600 EAST 39TH STREET
- City
- HASTINGS
- State
- NE
- ZIP
- 68901
- Mailing
- 600 EAST 39TH STREET, HASTINGS, NE 68901
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493120
- Employees
- 50
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 11, 2024
- Abate by
- Feb 11, 2026
- Penalty
- Initial $8,067 · Current $5,647 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the employer utilized storage rack systems with visible structural damage exposing employees to struck-by and crushing hazards: On or about July 25, 2024, employees engaged in material handling activities at the facility located at 600 East 39th Street, Hastings, Nebraska were exposed to crushing and struck-by hazards in that the employees were operating forklifts in close proximity to damaged warehouse racking in Room 6. The lower metal framework of the racking was bent, and three horizontal webbing beams were separated from the vertical column, creating a potential collapse of the racking system. Employees in the area are exposed to falling pallets and structural components of the racking. AMONG OTHER METHODS, FEASIBLE AND ACCEPTABLE ABATEMENT METHODS TO CORRECT THIS HAZARD ARE: i. Replace or repair any damaged columns, beams, or other structural component to restore the system to at least its original design capacity. ii. Install impact protection at the ends of aisles to protect racking uprights from damage. iii Train employees to recognize the dangers and to evaluate any hazards in regard to striking racking uprights. iv. Implement regular inspections of the rack system with the intent of identifying damage for repair or replacement.
Recent events (3)
- — F (S) $5646.9
- — C (S) $8067
- — Z (S) $8067
1910.178 A04
- Issued
- Dec 11, 2024
- Abate by
- Feb 11, 2026
- Penalty
- Initial $8,067 · Current $5,647 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: On or about July 25, 2024, employees engaged in material handling activities at the facility located at 600 East 39th Street, Hastings, Nebraska were exposed to struck-by hazards in that forklifts were being operated with a safety sensor that had been bypassed. The bypassed sensor detects when the forklift operator seat is not occupied and turns the vehicle off.
Recent events (3)
- — F (S) $5646.9
- — C (S) $8067
- — Z (S) $8067
1910.178 A06
- Issued
- Dec 11, 2024
- Abate by
- Feb 11, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates and markings were in place: On or about July 25, 2024, employees engaged in material handling activities at the facility located at 600 East 39th Street, Hastings, Nebraska were exposed to struck-by hazards in that forklifts were being operated without a legible weight capacity data plate to prevent overloading the forklift.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.178 Q07
- Issued
- Dec 11, 2024
- Abate by
- Feb 11, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: On or about July 25, 2024, employees engaged in material handling activities at the facility located at 600 East 39th Street, Hastings, Nebraska were exposed to struck-by hazards in that forklifts were not examined prior to use to identify conditions that would adversely affect the safety of the vehicle.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Dec 11, 2024
- Abate by
- Feb 11, 2026
- Penalty
- Initial $6,453 · Current $4,517 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about July 25, 2024, employees engaged in material handling activities at the facility located at 600 East 39th Street, Hastings, Nebraska were exposed to electrical shock hazards from a missing knockout on the pallet inverter control box.
Recent events (3)
- — F (O) $4517.1
- — C (S) $6453
- — Z (S) $6453
1910.303 B07 IV
- Issued
- Dec 11, 2024
- Abate by
- Feb 11, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by overheating: On or about July 25, 2024, employees engaged in material handling activities at the facility located at 600 East 39th Street, Hastings, Nebraska were exposed to electrical shock hazards from loose conduit and a missing knockout in the following instances: i. The light switch next to the garage door, had damage to the conduit that exposed wiring with insulation that was not designed for exposure to the elements. ii. The control box for the pallet inverter had conduit pulled out, exposing wiring with insulation that was not designed for exposure to the elements.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 493120)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347645004.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.