BLOOMINGDALE, IL —
OSHA Inspection: G2 HINGE COMPANY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of G2 HINGE COMPANY in 210 COVINGTON DRIVE, BLOOMINGDALE, IL 60108 (NAICS 332510). OSHA activity number 347645350.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- G2 HINGE COMPANY
- Site address
- 210 COVINGTON DRIVE
- City
- BLOOMINGDALE
- State
- IL
- ZIP
- 60108
- Mailing
- 210 COVINGTON DRIVE, BLOOMINGDALE, IL 60108
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332510
- Employees
- 55
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Jan 2, 2025
- Abate by
- Feb 24, 2025
- Penalty
- Initial $11,292 · Current $5,650 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. On or about July 25, 2024, and August 6, 2024, employees were not trained on hazardous energy sources. Employees did not have the knowledge, skills, required for the safe application, usage and removal of the energy sources while performing servicing and maintenance, therefore, employees were exposed to crushing hazards while placing their hand(s) under the die to feed material and make adjustments to the spacers/screws without de-energizing following machines. a. Minster mechanical power press 2 Line 6 b. Minster mechanical power press 2 Line 12 Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $5650
- — Z (S) $11292
1910.212 A01
- Issued
- Jan 2, 2025
- Penalty
- Initial $6,453 · Current $3,250 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about August 6, 2024, an employee was exposed to unguarded nip points on but not limited to the H-11 press brake between the ram and the die when the machine is in operation. b. An employee is exposed to a nip point while feeding the wire and adjusting it throughout the shift on mechanical power press 2 Line 6 . The wire is fed into the curler on the machine and then closes and completes the hinge. No abatement or documentation is required for this citation.
Recent events (2)
- — I (S) $3250
- — Z (S) $6453
1910.217 C01 I
- Issued
- Jan 2, 2025
- Abate by
- Apr 23, 2025
- Penalty
- Initial $8,067 · Current $4,100 Reduced
General-duty citation text
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es). On or about August 6, 2024, and thereafter employees were exposed to but not limited to nip points and pinch points on the following mechanical power presses: a. Employees were exposed to pinch points while the press was in operation due to there were no safeguards installed around the dies on the Minster mechanical power press 2 line 6. b. Employees were exposed to pinch points while the press was in operation due to there were no safeguards installed around the dies on the Minister mechanical power press 2 line 12. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (3)
- — P (S) $4100
- — I (S) $4100
- — Z (S) $8067
More inspections in this industry (NAICS 332510)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347645350.