Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: CINTAS CORPORATION NO. 2

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CINTAS CORPORATION NO. 2 in 300 HIGHLAND CORPORATE DRIVE, CUMBERLAND, RI 02864 (NAICS 561720). OSHA activity number 347645814.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cintas Corporation NO. 2 for free Get an email when a new federal OSHA severe-injury report for Cintas Corporation NO. 2 is published. One employer, no account, unsubscribe in one click.
Site address
300 HIGHLAND CORPORATE DRIVE
City
CUMBERLAND
State
RI
ZIP
02864
Mailing
300 HIGHLAND CORPORATE DRIVE, CUMBERLAND, RI 02864
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561720
Employees
200
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 8, 2024
Abate by
Dec 27, 2024
Penalty
Initial $16,131 · Current $12,131 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.   (a) Worksite, conveyor line #M15-17: On or about 7/24/2024, a maintenance employee did not utilize lockout/tagout procedures while rotating a conveyor system with the guards removed and, therefore, was exposed to ingoing nip points.
Recent events (3)
  • · F (S) $12131
  • · C (S) $16131
  • · Z (S) $16131

1910.147 C06 II

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Nov 8, 2024
Abate by
Dec 27, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed.   (a) Worksite, conveyor line #M15-17: On or about 7/24/2024, the employer did not certify that a periodic inspection of the energy control procedures was performed at least annually to ensure that the procedure and the requirement of this standard were being followed thus exposing employees to caught-in-between and struck-by hazards.
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

View Cintas Corporation NO. 2's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347645814.