LITTLETON, CO —
OSHA Inspection: CENTENNIAL CONCRETE & WATERPROOFING LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CENTENNIAL CONCRETE & WATERPROOFING LLC in 7501 S. UTICA DR., LITTLETON, CO 80128 (NAICS 238390). OSHA activity number 347647182.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CENTENNIAL CONCRETE & WATERPROOFING LLC
- Site address
- 7501 S. UTICA DR.
- City
- LITTLETON
- State
- CO
- ZIP
- 80128
- Mailing
- 15253 E. FREMONT DR., CENTENNIAL, CO 80112
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238390
- Employees
- 60
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.57 F05 I
- Issued
- Dec 4, 2024
- Abate by
- Mar 31, 2025
- Penalty
- Initial $9,680 · Current $9,680
9000
General-duty citation text
29 CFR 1926.57(f)(5)(i): Employers did not use only respirators approved by NIOSH under 42 CFR part 84 for protecting employees from dusts produced during abrasive-blasting operations: a) Location: Mountain Gate Apartments - 7501 S. Utica Dr., Littleton, CO 80128. On or about July 16, 2024, and at times prior, the employer, Centennial Concrete & Waterproofing LLC, did not require the use of Type CE Supplied Air Respirators when employees were required to engage in abrasive blasting operations using steel shot abrasive media to abrade approximately 464 square feet of concrete floor surface, in the enclosed breezeways and landings of Building 19. The employer required employees to wear air-purifying respirators with N95 filters and safety glasses. This condition exposed employees to respirable crystalline silica dust and eye injuries from rebounding steel shot abrasive media and debris.
Recent events (2)
- — I (O) $9680
- — Z (S) $9680
1926.1153 G04
- Issued
- Dec 4, 2024
- Abate by
- Jan 3, 2025
- Penalty
- Initial $9,680 · Current $0 Reduced
9000
General-duty citation text
29 CFR 1926.1153(g)(4): The employer did not designate a competent person to make frequent and regular inspections of job sites, materials, and equipment to implement the written exposure control plan: a) Location: Mountain Gate Apartments - 7501 S. Utica Dr., Littleton, CO 80128. On or about July 16, 2024, and at times prior, the employer, Centennial Concrete & Waterproofing LLC, did not ensure that a competent person implemented a written exposure control plan and frequently inspected work operations and equipment to control employee exposure to respirable crystalline silica dust during abrasive blasting and dry grinding of concrete surfaces, as well as concrete dust clean-up operations in Building 19. These conditions exposed employees to respirable crystalline silica dust.
Recent events (2)
- — I (S) $0
- — Z (S) $9680
1926.1153 C01
- Issued
- Dec 4, 2024
- Abate by
- Jan 3, 2025
- Penalty
- Initial $19,359 · Current $0 Reduced
9000
General-duty citation text
29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1: a) Location: Mountain Gate Apartments - 7501 S. Utica Dr., Littleton, CO 80128. On or about July 16, 2024, and at times prior, the employer, Centennial Concrete & Waterproofing LLC, did not ensure engineering controls listed in Table 1 were implemented during dry concrete grinding operations for uses other than mortar removal and for a working time period of greater than 4 hours. Employees were required to grind dry concrete surfaces in an enclosed area with a 7-inch Makita powered grinder. The employer did not ensure the Makita grinder was equipped with a grinding wheel or blade shroud as well as a dust collection system that provided 25 cubic feet per minute (cfm) or greater of airflow per inch of grinding wheel diameter, a filter with 99% or greater efficiency, and a cyclonic pre-separator or filter-cleaning mechanism. This condition exposed employees to respirable crystalline silica. Centennial Concrete & Waterproofing LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection 1705321, Citation 1, Item 3a, which was affirmed as a final order on May 2, 2024, with respect to the workplace located at 5105 DTC Pkwy. Greenwood Village, CO 80111.
Recent events (2)
- — I (R) $0
- — Z (R) $19359
1926.1153 D02 I
- Issued
- Dec 4, 2024
- Abate by
- Mar 31, 2025
- Penalty
- Initial $0 · Current $19,359
9000
General-duty citation text
29 CFR 1926.1153(d)(2)(i): The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section: a) Location: Mountain Gate Apartments - 7501 S. Utica Dr., Littleton, CO 80128. On or about July 16, 2024, and at times prior, the employer, Centennial Concrete & Waterproofing LLC, did not assess the exposure of each employee engaged in work operations which reasonably could be expected to expose employees to respirable crystalline silica at or above the action level. Employees were required to engage in abrasive blasting and dry grinding of concrete surfaces, as well as subsequent concrete dust clean-up using a Milwaukee battery-powered blower in the enclosed breezeways and landings of Building 19. These conditions exposed employees to respirable crystalline silica dust. Centennial Concrete & Waterproofing LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection 1705321, Citation 1, Item 3b, which was affirmed as a final order on May 2, 2024, with respect to the workplace located at 5105 DTC Pkwy. Greenwood Village, CO 80111.
Recent events (2)
- — I (S) $19359
- — Z (R) $0
1926.1153 G01
- Issued
- Dec 4, 2024
- Abate by
- Jan 3, 2025
- Penalty
- Initial $0 · Current $0
9000
General-duty citation text
29 CFR 1926.1153(g)(1): The employer did not establish and implement a written exposure control plan: a) Location: Mountain Gate Apartments - 7501 S. Utica Dr., Littleton, CO 80128. On or about July 16, 2024, and at times prior, the employer, Centennial Concrete & Waterproofing LLC, did not ensure a site- or task-specific written exposure plan was implemented to control employee exposure to respirable crystalline silica during required abrasive blasting and dry grinding of concrete surfaces, as well as subsequent concrete dust clean-up operations using a Milwaukee battery-powered blower in the enclosed breezeways and on landings of Building 19. These conditions exposed employees to respirable crystalline silica dust. Centennial Concrete & Waterproofing LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection 1705321, Citation 1, Item 3c, which was affirmed as a final order on May 2, 2024, with respect to the workplace located at 5105 DTC Pkwy. Greenwood Village, CO 80111.
Recent events (2)
- — I (R) $0
- — Z (R) $0
1926.1153 E02
- Issued
- Dec 4, 2024
- Abate by
- Jan 3, 2025
- Penalty
- Initial $19,359 · Current $0 Reduced
9000
General-duty citation text
29 CFR 1926.1153(e)(2): Where respirator use is required by this section, the employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134: a) Location: Mountain Gate Apartments - 7501 S. Utica Dr., Littleton, CO 80128. On or about July 16, 2024, and at times prior, the employer, Centennial Concrete & Waterproofing LLC, did not ensure a written respiratory protection program was effectively implemented when the use of Type CE Supplied Air Respirators was necessary as employees were required to engage in abrasive blasting of concrete surfaces in the enclosed breezeways and on landings of Building 19. This condition exposed employees to respirable crystalline silica dust and struck-by hazards from abrasive blast media. Centennial Concrete & Waterproofing LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection 1705321, Citation 1, Item 4a, which was affirmed as a final order on May 2, 2024, with respect to the workplace located at 5105 DTC Pkwy. Greenwood Village, CO 80111.
Recent events (2)
- — I (R) $0
- — Z (R) $19359
More inspections at Centennial Concrete & Waterproofing LLC
View Centennial Concrete & Waterproofing LLC's full OSHA safety record →
More inspections in this industry (NAICS 238390)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347647182.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.