Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VENTURE CIRCLE INTERNATIONAL LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VENTURE CIRCLE INTERNATIONAL LLC in 140 MARITIME DRIVE, SANFORD, FL 32771 (NAICS 337215). OSHA activity number 347649733.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Venture Circle International LLC — free Get an email when a new federal OSHA severe-injury report for Venture Circle International LLC is published. One employer, no account, unsubscribe in one click.
Site address
140 MARITIME DRIVE
City
SANFORD
State
FL
ZIP
32771
Mailing
140 MARITIME DRIVE, SANFORD, FL 32771
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
337215
Employees
24
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 18 exposed
Issued
Nov 19, 2024
Penalty
Initial $6,453 · Current $3,227 Reduced
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees   a. On or about July 29, 2024, at the site, employees were exposed to struck-by hazards, while working in and around the storage racks where the racks were not anchored and bolted to the floor.
Recent events (2)
  • — I (S) $3226.5
  • — Z (S) $6453

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 19, 2024
Penalty
Initial $6,453 · Current $3,227 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.   a. On or about July 29, 2024, at the riveting area, the employer exposed employees to cruising and puncture hazards, in that guards were not provided to employees while they operated a Touch O Matic Model number 300-2-03 Serial number 93-C-20220.
Recent events (2)
  • — I (S) $3226.5
  • — Z (S) $6453

1910.303 G01 II

Serious Gravity 1 3 instances 18 exposed
Issued
Nov 19, 2024
Penalty
Initial $4,839 · Current $2,420 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage.   a. On or about July 29, 2024, e-comers packing, the employer exposed employees to electrical fire hazards, in that the working space below and in front of the electrical panel was used for storage.  b. On or about July 29, 2024, pallet area, the employer exposed employees to electrical fire hazards, in that the working space below and in front of the electrical panel was used for storage.  c. On or about July 29, 2024, doors materials, the employer exposed employees to electrical fire hazards, in that the working space below and in front of the electrical panel was used for storage.
Recent events (2)
  • — I (S) $2419.5
  • — Z (S) $4839

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 19, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.   a.  On or about July 29, 2024, at the riveting department,  employees were exposed to electrical shock hazards, in that an opening to an electrical box on the Touch O Matic Model number 300-2-03 Serial number 93-C-20220 machine exposed live wiring.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 19, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.   a. On or about July 29, 2024, at the riveting area, employees were exposed to electrical hazards, in that an extension cord was being used as substitute of fixed wiring to power a Touch O Matic riveting machine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Venture Circle International LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347649733.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.