OSHA Inspection: U.S. DEPARTMENT OF AGRICULTURE - U.S. FOREST SERVICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPARTMENT OF AGRICULTURE - U.S. FOREST SERVICE in 161 EAST 1ST ST. DOOR B, ANCHORAGE, AK 99501 (NAICS 115310). OSHA activity number 347652034.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of Agriculture - U.S. Forest Service — free Get an email when a new federal OSHA severe-injury report for U.S. Department of Agriculture - U.S. Forest Service is published. One employer, no account, unsubscribe in one click.
Site address
161 EAST 1ST ST. DOOR B
City
ANCHORAGE
State
AK
ZIP
99501
Mailing
161 EAST 1ST ST. DOOR 8, ANCHORAGE, AK 99501
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
115310
Employees
25
Ownership type
D

5 citations on file for this inspection.

1910.22 C

Serious Gravity 5 2 instances 25 exposed
Issued
Nov 4, 2024
Abate by
Nov 15, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.22(c):  The employer did not provide, and ensure each employee uses, a safe means of access and egress to and from walking-working surfaces.   a)  Occupant Office:  On or about July 11, 2024, boxes of files blocked an egress path, exposing employees to fire hazards   b)  Occupant Office:  On or about July 11, 2024, boxes of files blocked an egress path, exposing employees to fire hazards
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 3 instances 25 exposed
Issued
Nov 4, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2):  Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a)  Office G95:  On or about July 11, 2024 a Relocatable Power Tap (RPT/Surge Protector) was connected to another RPT, exposing employees to fire and electrical shock hazards.  b)  Office H05:  On or about July 11, 2024 a Relocatable Power Tap (RPT/Surge Protector) was connected to another RPT, exposing employees to fire and electrical shock hazards.  c)  Office Near Break Room:  or about July 11, 2024 a Relocatable Power Tap (RPT/Surge Protector) was connected to an extension cord, exposing employees to fire and electrical shock hazards.
Recent events (1)
  • — Z (S) $0

1910.303 G01 I B

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 4, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i)(B):  For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of the working space in front of electrical equipment was less than the width of the equipment or 762 mm (30 inches), whichever was greater :  a) Lab:  On or about July 11, 2024, a step ladder was leaning on the main electrical breaker, exposing employee to electrical hazards.
Recent events (1)
  • — Z (S) $0

1910.151 B

Other-than-serious 2 instances 25 exposed
Issued
Nov 4, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.151(b):  First aid supplies approved by a consulting physician were not readily available:  a)  Mail Room, medical cabinets:  On or about July 11, 2024, first aid kits contained expired product, exposing employees to ineffective product hazards.  b)  Break Room Office medical cabinets:  On or about July 11, 2024,  first aid kits contained expired product, exposing employees to ineffective product hazards.
Recent events (1)
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 25 exposed
Issued
Nov 4, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2):  Portable fire extinguishers were not visually inspected at least monthly:  a)  Entry Hallway:  On or about Jul 11, 2024,  portable fire extinguishers monthly visual inspections were not being conducted, exposing employees to fire hazards.
Recent events (1)
  • — Z (O) $0

View U.S. Department of Agriculture - U.S. Forest Service's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347652034.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.