TAMPA, FL ·
OSHA Inspection: VANBUREN'S TREE SERVICE, LLC
Fatality or catastrophe inspection · Safety discipline
At a glance
On , OSHA opened a fatality or catastrophe safety inspection of VANBUREN'S TREE SERVICE, LLC in 2115 E. NEDRO RD., TAMPA, FL 33604 (NAICS 561730). OSHA activity number 347653289.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VANBUREN'S TREE SERVICE, LLC
- Site address
- 2115 E. NEDRO RD.
- City
- TAMPA
- State
- FL
- ZIP
- 33604
- Mailing
- 9402 N 10TH ST, TAMPA, FL 33612
What kind of inspection was it?
- Inspection type
- Fatality or catastrophe (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561730
- Employees
- 5
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.67 C02 V
- Issued
- Jan 29, 2025
- Abate by
- Feb 25, 2025
- Penalty
- Initial $4,965 · Current $1,738 Reduced
General-duty citation text
29 CFR 1910.67(c)(2)(v): A personal fall arrest or travel restraint system that meets the requirements in subpart I of this part was not worn and attached to the boom or basket when working from an aerial lift: a) On or about July 30, 2024, in the side yard, an employee working from a NiftyLift aerial lift was trimming trees without personal fall protection and exposed to an approximate 40 foot fall hazard.
Recent events (3)
- · F (S) $1737.75
- · C (S) $4965
- · Z (S) $4965
1910.333 C03
- Issued
- Jan 29, 2025
- Abate by
- Feb 25, 2025
- Penalty
- Initial $16,550 · Current $5,793 Reduced
General-duty citation text
29 CFR 1910.333(c)(3):When work was to be performed near overhead lines, the lines were not deenergized and grounded, nor were other protective measures provided before work was started: a) On or about July 30, 2024, in the front yard, an employee working from and maneuvering a NiftyLift aerial lift near energized overhead powerlines and exposed to a 7,200-volt electrical hazard.
Recent events (3)
- · F (S) $5792.5
- · C (S) $16550
- · Z (S) $16550
1910.333 C03 I A 1
- Issued
- Jan 29, 2025
- Abate by
- Feb 25, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(c)(3)(i)(A)(1): Unqualified employees working in an elevated position near overhead lines with voltages to ground rated at 50 kV or below and their conductive tools were not kept greater than 10-feet from from unguarded energized overhead lines: a)On or about July 30, 2024, in the front yard, an employee working from and maneuvering a NiftyLift aerial lift was exposed to an electrocution hazard in that, the lift with a Stihl pruner pole saw within 6 feet of an energized 7,200 volt unguarded overhead powerlines.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 561730)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347653289.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.