FORT WORTH, TX —
OSHA Inspection: BANDERA UTILITY CONTRACTORS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BANDERA UTILITY CONTRACTORS, LLC in 1900 BLUE MOUND ROAD WEST MARLOWE WELLINGTON HYBRID, FORT WORTH, TX 76131 (NAICS 237110). OSHA activity number 347653461.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BANDERA UTILITY CONTRACTORS, LLC
- Site address
- 1900 BLUE MOUND ROAD WEST MARLOWE WELLINGTON HYBRID
- City
- FORT WORTH
- State
- TX
- ZIP
- 76131
- Mailing
- 5750 GENESIS COURT SUITE 100, FRISCO, TX 75034
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 20
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.651 C02
- Issued
- Dec 23, 2024
- Abate by
- Jan 23, 2025
- Penalty
- Initial $13,690 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: On or about July 30, 2024, on the southwest side of the jobsite; employee(s) worked in a trench without a means of egress within 25-feet or less from where work was performed.
Recent events (2)
- — I (S) $0
- — Z (S) $13690
1926.651 K02
- Issued
- Dec 23, 2024
- Abate by
- Jan 23, 2025
- Penalty
- Initial $15,970 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety: On or about July 30, 2024, on the southwest side of the jobsite, employee(s) worked in a trench where hazards were observed and were not removed by the competent person.
Recent events (2)
- — I (S) $0
- — Z (S) $15970
1926.1053 B16
- Issued
- Dec 23, 2024
- Abate by
- Jan 23, 2025
- Penalty
- Initial $13,690 · Current $8,214 Reduced
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: On or about July 30, 2024, on the southwest side of the jobsite; a defective portable ladder was used by employee(s) in a trench to perform work.
Recent events (2)
- — I (S) $8214
- — Z (S) $13690
1926.652 A01
- Issued
- Dec 23, 2024
- Abate by
- Jan 23, 2025
- Penalty
- Initial $31,939 · Current $31,939
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 1926.652(b)(3)(i): On or about July 30, 2024, on the southwest side of the jobsite, employee(s) were working in a trench without an adequate protective system.
Recent events (2)
- — I (S) $31939
- — Z (R) $31939
1926.1053 B01
- Issued
- Dec 23, 2024
- Abate by
- Jan 23, 2025
- Penalty
- Initial $31,939 · Current $31,939
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about July 30, 2024, on the southwest side of the jobsite, employee(s) who worked in a trench utilized a portable ladder that was not extended at least three (3) feet above the upper landing surface. Bandera Utility Contractors LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.1053(b)(1), which was contained in OSHA inspection number 1604239, citation number one (1), item number two (2) and was affirmed as a final order on March 11, 2024, with respect to a workplace located at 4643 FM 453 in McKinney, TX.
Recent events (2)
- — I (S) $31939
- — Z (R) $31939
More inspections in this industry (NAICS 237110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347653461.