Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PSE&G FLEET MAINTENANCE

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PSE&G FLEET MAINTENANCE in 350 RARITAN CENTER PARKWAY, EDISON, NJ 08837 (NAICS 811198). OSHA activity number 347653560.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pse&G Fleet Maintenance — free Get an email when a new federal OSHA severe-injury report for Pse&G Fleet Maintenance is published. One employer, no account, unsubscribe in one click.
Site address
350 RARITAN CENTER PARKWAY
City
EDISON
State
NJ
ZIP
08837
Mailing
350 RARITAN CENTER PARKWAY, EDISON, NJ 08837
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811198
Employees
50
Ownership type
A

3 citations on file for this inspection.

1910.147 A03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 22, 2025
Penalty
Initial $9,931 · Current $9,931
29 CFR  1910.147(a)(3)(i): The employer did not utilize procedures for affixing appropriate lockout devices or tagout devices to energy isolating devices, and to otherwise disable machines or equipment to prevent unexpected energization, start up or release of stored energy in order to prevent injury to employees.   a) PSE&G Fleet Maintenance, 350 Raritan Center Parkway, Edison, NJ 08837 - Shop: The employer did not ensure that employees who operate the Radial Drill Press utilize procedures to otherwise disable machines or equipment to prevent unexpected energization, start up or release of stored energy in order to prevent injury to employees,  exposing employees to caught in and amputation hazards.  Violation observed on or about 7/30/2024.
Recent events (2)
  • — I (S) $9931
  • — Z (S) $9931

1910.147 D04 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jan 22, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:   a) PSE&G Fleet Maintenance, 350 Raritan Center Parkway, Edison, NJ 08837 - Shop: The employer did not ensure that employees isolate hazardous energy sources when  replacing a drill bit in a radial drill press, exposing employees to caught in and amputation hazards.  Violation observed on or about 7/30/2024.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Jan 22, 2025
Abate by
Feb 10, 2025
Penalty
Initial $9,931 · Current $9,931
29 CFR  1910.212(a)(3)(ii): The  point of operation of machines whose operation exposed an employee to injury, was not guarded:   a) PSE&G Fleet Maintenance, 350 Raritan Center Parkway, Edison, NJ 08837 - Shop: The employer did not ensure that a guard was in place on the radial drill press , to prevent employee(s) from having any part of their body in the danger zone(s) during operation. This condition exposed employees to amputation hazards.   Violation observed on or about 7/30/2024.
Recent events (2)
  • — I (O) $9931
  • — Z (S) $9931

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347653560.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.