Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RC ROOFING & SIDING LLC in 2249 3RD AVENUE, NEW BRIGHTON, PA 15066 (NAICS 238160). OSHA activity number 347664567.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RC ROOFING & SIDING LLC
- Site address
- 2249 3RD AVENUE
- City
- NEW BRIGHTON
- State
- PA
- ZIP
- 15066
- Mailing
- 805 GRAY STREET, MC KEES ROCKS, PA 15136
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B10
- Issued
- Aug 21, 2024
- Penalty
- Initial $3,457 · Current $1,800 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: a) Job site, 2249 3rd Avenue, New Brighton, PA: On or about August 5, 2024, during standing seam metal roof work activities, the employer did not ensure that appropriate fall protection systems/devices were used where fall hazards of at least 16 feet existed.
Recent events (2)
- — I (S) $1800
- — Z (S) $3457
1926.1053 B01
- Issued
- Aug 21, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access; or, when such an extension was not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that would not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder: a) Job site, 2249 3rd Avenue, New Brighton, PA: On or about August 5, 2024, during standing seam metal roof work activities, the employer did not ensure that the ladder used to gain access to/from the roof was properly set up in that it only extended approximately 2 feet above the roof line.